50
Permission of Run command
This function allows you to accept run command.
Option
Code
Terminal
Symbol
Function Name
State
Description
84
ROK
Permission of Run
command
ON
Run command can be accepted
OFF Run command is ignored
Valid for inputs:
C001
~
C007
Example (default input configuration
shown—see
page 3–84
):
See I/O specs on
page 4–6.
Required settings
Notes:
Rotation direction detection
Input terminal (7) is for inputting “B pulse”, which is used for detecting the rotation
direction.
Option
Code
Terminal
Symbol
Function Name
State
Description
85
EB Rotation
direction
detection
ON
OFF
Valid for inputs:
C007
Example (default input configuration
shown—see
page 3–84
):
See I/O specs on
page 4–6.
Required settings
Notes:
EB input terminal is dedicated terminal (7).
Maximum allowable input frequency is 2kHz.
Display limitation
This function is to show only the contents of
d001
display.
Option
Code
Terminal
Symbol
Function Name
State
Description
86
DISP Display
limitation
ON
OFF
Valid for inputs:
C001
~
C007
Example (default input configuration
shown—see
page 3–84
):
See I/O specs on
page 4–6.
Required settings
Notes:
ROK
7
6
5
4
3
2
1
L
PCS
P24
DISP
7
6
5
4
3
2
1
L
PCS
P24
PLC
PLC
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...