C
−
24
“C” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Lnitial
data
Units
C102
Reset selection
Determines response to Reset
input [RS].
Four option codes:
00
…
Cancel trip state at input
signal ON transition, stops
inverter if in Run Mode
01
…
Cancel trip state at signal
OFF transition, stops inverter
if in Run Mode
02
…
Cancel trip state at input ON
transition, no effect if in Run
Mode
03
…
Clear the memories only
related to trip status
U
00
−
C103
Restart mode after reset
Determines the restart mode after
reset is given, three option codes:
00
…
Start with 0 Hz
01
…
Start with freq. matching
02
…
Start with active freq.
matching
U
00 -
C104
UP/DWN clear mode
Freq. set value when UDC signal is
given to the input terminal, two
option codes:
00
…
0 Hz
01
…
Original setting (in the
EEPROM memory at power
on)
U
00 -
C105
EO gain adjustment
Set range is 50 to 200%
9
100. %
C106
AM gain adjustment
Set range is 50 to 200%
9
100. %
C109
AM bias adjustment
Set range is 0 to 100%
9
0. %
C111
Overload warning level 2
Sets the overload warning signal
level between 0% and 200% (from 0
to two time the rated current of the
inverter)
9
Rated
current
x 1.15
A
C130
Output [11] on delay
Set range is 0.0 to 100.0 sec.
U
0.0 Sec.
C131
Output [11] off delay
U
0.0 Sec.
C132
Output [12] on delay
Set range is 0.0 to 100.0 sec.
U
0.0 Sec.
C133
Output [12] off delay
U
0.0 Sec.
C140
Relay output on delay
Set range is 0.0 to 100.0 sec.
U
0.0 Sec.
C141
Relay output off delay
U
0.0 Sec.
C142
Logic output 1 operand A
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
U
00
−
C143
Logic output 1 operand B
U
00
−
C144
Logic output 1 operator
Applies a logic function to calculate
[LOG] output state,
Three options:
00
…
[LOG] = A AND B
01
…
[LOG] = A OR B
02
…
[LOG] = A XOR B
U
00
−
C145
Logic output 2 operand A
All the programmable functions
available for logic (discrete) outputs
except LOG1 to LOG3, OPO, no
U
00
−
C146
Logic output 2 operand B
U
00
−
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...