3
−
57
Display related parameters
Function code display restriction:
b037
–
The function code display restriction allows
you to arbitrarily switch the display mode or the display content on the integrated
operator.
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Lnitial data Units
b037
Function code display
restriction
Seven option codes:
00
…
Full display
01
…
Function-specific display
02
…
User setting (and
b037
)
03
…
Data comparison display
04
…
Basic display
05
…
Monitor display only
U
04
−
(1)
Function-specific display mode (
b037
=
01
)
If a specific function has not been selected, the monitor does not show the
parameters concerning the specific function. Following table lists the details of
display conditions.
No. Displayed
conditions Displayed func. codes when condition fulfilled.
1 2nd
motor
C001...C007=08
F202, F203, A201 to A204, A220, A244, A245,
A261, A262, A281, A282, A292 to A296, b212,
b213, b221 to b223, C241, H202 to H204, H206
2
EzSQ
A017=01,02
d023 to d027, P100 to P131
3
Sensorless vector control
A044=03
d009, d010, d012, b040 to b046, C054 to C059,
H001, H005, H020 to H024, H030 to H034, P033,
P034, P036 to P040
4
Sensorless vector control
for 2nd motor
C001...C007=08
AND A244=03
d009, d010, d012, b040 to b046, C054 to C059,
H001, H205, H220 to H224, H230 to H234, P033,
P034, P036 to P040
5
Free V/F control
A044=02 OR
C001...C007=08 AND
A244=02
b100 to b113
6
Free setting of
electronic-thermal
b013=02 OR
C001...C007=08 AND
b213=02
b015 to b020
7
VC or VP
1.7
control
A044=00,01
A041 to A043,A046, A047
8
VC or VP
1.7
control for 2nd
motor
C001...C007=08 AND
A244=00,01
A241 to A243, A246, A247
9 DC
breaking
A051=01,02 OR
C001...C007=07
A052 to A059
10 PID
A071=01,02
d004, A072 to A079, A156, A157, C044, C052,
C053
11
EzCOM
C096=01,02
C098 to C100, P140 to P155
12
Curving accel/deceleration
A097,A098=01...04
A131, A132, A150 to A153
13 Controlled
deceleration
b050=01,02,03
b051 to b054
14
Breaking
b120=01
b121 to b127
15
Decel. overvolt. suppress
b130=01,02
b131 to b134
16 Simple
positioning
P003=01
d008, P004, P011, P012, P015, P026, P027,
P060to P073, P075, P077, H050, H051
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...