3
−
8
“d” Function
Run
Mode
Edit
Units
Func.
Code
Name
Description
D007
Scaled output frequency
monitor
Displays the output frequency
scaled by the constant in
B086
.
Decimal point indicates range:
0 to 3999
−
Hz times
constant
d008
Actual
frequency
monitor
Displays the actual frequency,
range is -400 to 400 Hz
−
Hz
d009
Torque
command
monitor
Displays the torque command,
range is -200 to 200 %
−
%
d010
Torque bias monitor
Displays the torque bias value,
range is -200 to 200 %
−
%
d012
Output torque monitor
Displays the output torque, range is
-200 to 200 %
−
%
D013
Output voltage monitor
Voltage of output to motor,
Range is 0.0 to 600.0V
−
V
d014
Input power monitor
Displays the input power, range is 0
to 999.9 kW
−
KW
d015
Watt-hour monitor
Displays watt-hour of the inverter,
range is 0 to 9999000
−
D016
Elapsed RUN time monitor
Displays total time the inverter has
been in RUN mode in hours.
Range is 0 to 9999 / 1000 to 9999 /
⎡
100 to
⎡
999 (10,000 to 99,900)
−
hours
D017
Elapsed power-on time
monitor
Displays total time the inverter has
been powered up in hours.
Range is 0 to 9999 / 1000 to 9999 /
⎡
100 to
⎡
999 (10,000 to 99,900)
−
hours
D018
Heat sink temperature
monitor
Temperature of the cooling fin,
range is -20~150
−
°
C
d022
Life check monitor
Displays the state of lifetime of
electrolytic capacitors on the PWB
and cooling fan.
−
−
d023
Program counter monitor
[EzSQ]
Range is 0 to 1024
−
−
d024
Program number monitor
[EzSQ]
Range is 0 to 9999
−
−
d025
User monitor 0
[EzSQ]
Result of EzSQ execution, range is
–2147483647~2147483647
−
−
d026
User monitor 1
[EzSQ]
Result of EzSQ execution, range is
–2147483647~2147483647
−
−
d027
User monitor 2
[EzSQ]
Result of EzSQ execution, range is
–2147483647~2147483647
−
−
d029
Positioning command
monitor
Displays the positioning command,
range is –268268435455
−
−
d030
Current position monitor
Displays the current position, range
is –268268435455
−
−
d050
Dual
monitor
Displays two different data
configured in
b160
and
b161
.
−
−
d060
Inverter mode monitor
Displays currently selected inverter
mode :
I-C:IM CT mode/I-v:IM VT mode/
P:PM
−
−
Lifetime expired
Normal
Electrolytic caps
Cooling fan
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...