4
−
73
Option
Code
Terminal
Symbol
Function Name
State
Description
31
FBV Feedback
Value
Check
ON
•
Transitions to ON when the inverter is in RUN
Mode and the PID Process Variable (PV) is less
than the Feedback Low Limit (
C053
)
OFF
•
Transitions to OFF when the PID Feedback Value
(PV) exceeds the PID High Limit (
C052
)
•
Transitions to OFF when the inverter goes from
Run Mode to Stop Mode
Valid for inputs:
11, 12, AL0 – AL2
Example for terminal [11] (default output
configuration shown – see
page 3-90
):
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration – see
page 4-52 and 3-90
):
See I/O specs on
page 4-6
Required settings
A076
,
C052
,
C053
Notes:
•
The [FBV] is designed for implementing two-stage
control. The PV high limit and PV low limit
parameters,
C052
and
C053
, do not function as
process alarm thresholds. Terminal [FBV] does
not provide a PID alarm function.
•
The example circuit for terminal [11] drives a relay
coil. Note the use of a diode to prevent the
negative-going turn-off spike generated by the coil
from damaging the inverter’s output transistor.
RY
Inverter output
terminal circuit
CM2
11
FBV
AL1
Power
supply
Load
AL0
AL2
Inverter logic
circuit board
FBV
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...