4
−
46
Multistage-position switch (1)~(3)
When “
66
(CP1)” to “
68
(CP3)” are assigned to input terminals, you can select position
settings from multistage positions 0 to 7.
Use multistage position settings 0 to 7 (
P060
to
P067
) for the position settings. If no
position settings are assigned to terminals, multistage position 0 (
P060
) is assumed.
Position setting
Parameter
CP3
CP2
CP1
Multistage position 0
P060
0 0 0
Multistage position 1
P061
0 0 1
Multistage position 2
P062
0 1 0
Multistage position 3
P063
0 1 1
Multistage position 4
P064
1 0 0
Multistage position 5
P065
1 0 1
Multistage position 6
P066
1 1 0
Multistage position 7
P067
1 1 1
You can specify a delay to be applied at multistage position setting input, until the
relevant terminal input is determined. Use this specification to prevent the application
of fluctuating terminal input before it is determined.
You can adjust the determination time with the multistage speed/position
determination time setting (
C169
). The input data is finally determined when the
terminal input becomes stable after the delay set as
C169
. (Note that a long
determination time deteriorates the input terminal response.)
Option
Code
Terminal
Symbol
Function Name
State
Description
66
~
68
CP1~CP3 Multistage-position
switch
(1)~(3)
ON
Multistage position is defined by combination of
the inputs.
OFF
Valid for inputs:
C001
~
C007
Example (default input configuration
shown—see
page 3–84
):
See I/O specs on
page 4–6.
Required settings
P060
~
P067
Notes:
Position
command
ON
ON
ON
CP1
CP2
CP3
1
3
7
5
4
Determination time (
C169
)=0
Determination time
(
C169
) specified
Determination time (
C169
)
CP3 CP2
CP1
7
6
5
4
3
2
1
L
PCS
P24
PLC
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...