![Hitachi WJ200 Series Software Скачать руководство пользователя страница 266](http://html.mh-extra.com/html/hitachi/wj200-series-software/wj200-series-software_instruction-manual_140866266.webp)
4
−
63
Torque Limited Signal
The inverter outputs the torque limited signal when it is in torque limit operation.
To enable this function, assign “
10
(TRQ)” to an intelligent output terminal.
Refer to section 3 for detailed explanation.
Option
Code
Terminal
Symbol
Function Name
State
Description
10
TRQ Torque
limited
signal
ON
Inverter is in torque limiting mode
OFF
Inverter is not in torque limiting mode
Valid for inputs:
11, 12, AL0 – AL2
Example for terminal [11] (default output
configuration shown – see
page 3-90
):
Example for terminal [AL0], [AL1], [AL2] (requires
output configuration – see
page 4-52 and 3-90
):
See I/O specs on
page 4-6
Required settings
A044
=
03
,
b040
~
b044
Notes:
•
The example circuit for terminal [11] drives a relay
coil. Note the use of a diode to prevent the
negative-going turn-off spike generated by the coil
from damaging the inverter’s output transistor.
RY
Inverter output
terminal circuit
CM2
11
TRQ
AL1
Power
supply
Load
AL0
AL2
Inverter logic
circuit board
TRQ
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...