3
−
79
STO (Safe Torque Off) Setting
Please refer to the appendix E for detailed information.
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Lnitial data Units
b145
GS input mode
Two option codes:
00
…
No trip (Hardware shutoff
only)
01
…
Trip
U
00
−
Inverter Mode Setting
Besides Dual rating selection (b049), WJ200 supports two different operation modes,
standard mode and high frequency IM mode.
In high frequency IM mode, the max. output frequency is up to 1000Hz. Be sure to set
HD mode (b049=00) at first before switching to high frequency mode. In high frequency
mode, it cannot be changed to ND mode.
In high frequency mode, SLV mode is not available.
The inverter mode cannot be changed just setting
b171
. After setting
b171
, be sure to
execute initialization to activate new mode.
Actual inverter mode can be monitored with
d060
.
Once high frequency mode is set, initialization can be done just by setting
b084
,
b085
,
b094
and setting
b180
, it is not needed to set
b171
.
“b” Function
Run
Mode
Edit
Defaults
Func.
Code
Name
Description
Lnitial data Units
b171
Inverter mode selection
Three option codes:
00
…
No function
01
…
Std. IM (Induction Motor)
03
…
PM(Permanent Magnet
Motor)
U
00
−
Main differences between high frequency and std. mode are as follows.
Содержание WJ200 Series Software
Страница 19: ...xviii Revisions Revision History Table No Revision Comments Date of Issue Operation Manual No ...
Страница 59: ...2 14 Dimensional drawings continued Power Type W mm H mm D mm D1 mm 3 phase 200V WJ200 150LF 220 350 175 84 ...
Страница 295: ...4 92 Safe Stop Function To be finalized after TUV approval ...
Страница 296: ...5 1 5 Inverter System Accessories In This Chapter page Introduction 2 Component Description 3 ...
Страница 322: ...A 1 A Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 ...
Страница 378: ...B 49 Note 2 Be sure not to write into above 1F02h to 1F1Dh ...
Страница 382: ...C 1 Drive Parameter Setting Tables In This Appendix page Introduction 2 Parameter Settings for Keypad Entry 2 C ...