9.7 Message Reference
147
9
Set and Query Contact Check Threshold
Syntax
Command
:RESistance:CONTactcheck:LEVel
<Range>
,
<Level>
Query
Response
:RESistance:CONTactcheck:LEVel?
<Range>
<Level>
Command
:LPResistance:CONTactcheck:LEVel
<Range>
,
<Level>
Query
Response
:LPResistance:CONTactcheck:LEVel?
<Range>
<Level>
<Range>
=
(:RESistance) RNG100MIL/ RNG1000MIL/ RNG10/ RNG100/ RNG1000/ RNG10K/
RNG100K/ RNG1000K/ RNG10MEG/ RNG100MEG
(:LPResistance) RNG1000MIL/ RNG10/ RNG100/ RNG1000
<Level>
=
L1/ L2/ L3 / L4/ L5/ L6/ L7
Contact Check Error Threshold:
(L1: 50
/ L2: 100
/ L3: 150
/ L4: 200
/ L5: 300
/ L6: 400
/
L7: 500
)
Description
Sets the error threshold value for contact checking.
Set and Query Voltage Level Monitor Level
Syntax
Command
:RESistance:VMONitor
<Range>
,
<1/ 0/ ON/ OFF>
Query
Response
:RESistance:VMONitor?
<Range>
<ON/ OFF>
Command
:LPResistance:VMONitor
<Range>
,
<1/ 0/ ON/ OFF>
Query
Response
:LPResistance:VMONitor?
<Range>
<ON/ OFF>
<Range>
=
(:RESistance) RNG100MIL/ RNG1000MIL/ RNG10/ RNG100/ RNG1000/ RNG10K/
RNG100K/ RNG1000K/ RNG10MEG/ RNG100MEG
(:LPResistance) RNG1000MIL/ RNG10/ RNG100/ RNG1000
Description
Enables/disables the voltage level monitor function.
Set and Query Voltage Level Monitor Level
Syntax
Command
:RESistance:VMONitor:LEVel
<Range>
,
<Level>
Query
Response
:RESistance:VMONitor:LEVel?
<Range>
<Level>
Command
:LPResistance:VMONitor:LEVel
<Range>
,
<Level>
Query
Response
:LPResistance:VMONitor:LEVel?
<Range>
<Level>
<Range>
=
(:RESistance) RNG100MIL/ RNG1000MIL/ RNG10/ RNG100/ RNG1000/ RNG10K/
RNG100K/ RNG1000K/ RNG10MEG/ RNG100MEG
(:LPResistance) RNG1000MIL/ RNG10/ RNG100/ RNG1000
<Level>
=
L1/ L2/ L3
(L1: Loose/ L2: Normal/ L3: Severe)
Description
Sets the error level for the voltage level monitor function.
Содержание RM3542
Страница 2: ......
Страница 6: ...Contents iv ...
Страница 16: ...Operating Precautions 10 ...
Страница 26: ...1 3 Screen Organization 20 ...
Страница 32: ...2 3 Turning the Power On and Off 26 ...
Страница 46: ...3 8 Confirming Faulty Measurements 40 ...
Страница 64: ...4 12 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 58 ...
Страница 84: ...6 4 Auto Exporting Measured Values at End of Measurement Data Output Function 78 ...
Страница 90: ...7 3 Printing 84 ...
Страница 172: ...9 10 Device Compliance Statement 166 ...
Страница 190: ...11 4 Disposing of the Instrument 184 ...
Страница 200: ...Appendix 5 Dimensional Diagram A10 Appendix 5 Dimensional Diagram ...
Страница 214: ...Index Index 4 ...
Страница 215: ......
Страница 216: ......
Страница 217: ......
Страница 218: ......