Comparator
:CALCulate:LIMit:STATe
1/ 0/ ON/ OFF
Sets and queries the comparator oper-
ating state.
:CALCulate:LIMit:STATe?
[ON/ OFF]
:CALCulate:LIMit:BEEPer
OFF/ HI/ LO/ HL/ IN
Sets and queries the beep sound.
:CALCulate:LIMit:BEEPer?
[OFF/ HI/ LO/ HL/ IN]
:CALCulate:LIMit:MODE
ABS/ REF
Sets and queries the decision mode.
:CALCulate:LIMit:MODE?
[ABS/ REF]
:CALCulate:LIMit:ABS
<Upper threshold>,
<Lower threshold>
Sets and queries ABS mode upper/
lower comparator threshold values.
:CALCulate:LIMit:ABS?
[<Upper threshold>,
<Lower threshold>]
:CALCulate:LIMit:REFerence
<reference resistance>
Sets and queries REF% mode refer-
ence resistance.
:CALCulate:LIMit:REFerence?
[<reference resistance>]
:CALCulate:LIMit:PERCent
<Upper threshold (%)>,
<Lower threshold (%)>
Sets and queries REF% mode upper/
lower comparator threshold percent-
ages.
:CALCulate:LIMit:PERCent?
[<Upper threshold (%)>,
<Lower threshold (%)>]
:CALCulate:LIMit:RESult?
[HI/ IN/ LO/ OFF/ ERR]
Queries the comparator result.
Self-Calibration
:SYSTem:CALibration
Execute self-calibration.
:SYSTem:CALibration:AUTO
1/ 0/ ON/ OFF
Sets and queries the automatic self-
calibration.
:SYSTem:CALibration:AUTO?
[ON/ OFF]
Key Beeper
:SYSTem:BEEPer:STATe
1/ 0/ ON/ OFF
Sets and queries the key beeper.
:SYSTem:BEEPer:STATe?
[ON/ OFF]
Line Frequency
:SYSTem:LFRequency
AUTO/ 50/ 60
Sets and queries the AC line frequen-
cy.
:SYSTem:LFRequency?
[AUTO/ 50/ 60]
Key-Lock
:SYSTem:KLOCk
1/ 0/ ON/ OFF
Sets and queries the key-lock.
:SYSTem:KLOCk?
[ON/ OFF]
Header Present
:SYSTem:HEADer
1/ 0/ ON/ OFF
Sets and queries header present.
:SYSTem:HEADer?
[ON/ OFF]
EOM Output
:SYSTem:EOM:MODE
HOLD/ PULSe
Sets and queries the EOM output
mode.
:SYSTem:EOM:MODE?
[HOLD/ PULSE]
:SYSTem:EOM:PULSe
0.001 to 0.100
Sets and queries the EOM pulse width.
:SYSTem:EOM:PULSe?
[0.001 to 0.100]
Notes:
•
< >: contents of the data portion.
•
[ ]: Response data
Содержание RM3542
Страница 2: ......
Страница 6: ...Contents iv ...
Страница 16: ...Operating Precautions 10 ...
Страница 26: ...1 3 Screen Organization 20 ...
Страница 32: ...2 3 Turning the Power On and Off 26 ...
Страница 46: ...3 8 Confirming Faulty Measurements 40 ...
Страница 64: ...4 12 Compensating for Thermal EMF Offset Offset Voltage Compensation OVC 58 ...
Страница 84: ...6 4 Auto Exporting Measured Values at End of Measurement Data Output Function 78 ...
Страница 90: ...7 3 Printing 84 ...
Страница 172: ...9 10 Device Compliance Statement 166 ...
Страница 190: ...11 4 Disposing of the Instrument 184 ...
Страница 200: ...Appendix 5 Dimensional Diagram A10 Appendix 5 Dimensional Diagram ...
Страница 214: ...Index Index 4 ...
Страница 215: ......
Страница 216: ......
Страница 217: ......
Страница 218: ......