Chapter 11 DSNG Configuration
© 2013 Harmonic Inc. Harmonic All rights reserved.
309
Ellipse 3000 Release 3.0, Rev. B
L-Band Modulator Parameters
11.2.8
10 MHz Clock
The 10MHz Clock parameter enables providing an accurate 10 MHz reference clock for the next
up-converting level.
The 10 MHz Reference clock can be either embedded in the output stream OR physically provided
from the 10 MHz REF Clock connector on the L-Band front-end.
The available options are:
■
Off
– 10 MHz reference clock is available from the connector.
■
On
– 10 MHz reference clock is available embedded on the stream.
The 10 MHz Clock default is
Off
.
Front Panel
To set the source of the 10 MHz Clock parameter on the front panel:
❖
Navigate
Root > L-Band Modulation and Up-Converter > 10 MHz Clock
.
Web Manager
To set the 10 MHz Clock parameter in the Web Manager:
❖
Select
DSNG > Modulator and Up-Converter
10 MHz Clock
ƒ Off