Chapter 10 Unit Configuration
© 2013 Harmonic Inc. Harmonic All rights reserved.
291
Ellipse 3000 Release 3.0, Rev. B
Alarm Sub-Menu/Tab
Management Port Disconnected
Management port address is not valid
Data Port disconnected
Data port address is not valid
BOOTP failed
Wrong BOOTP parameters for encoder
Wrong Boot File name
BOOTP parameters not suitable for encoder
TFTP Failed
Failure to connect to the TFTP server.
ZAP Failed
NMX ZAP failed
AP_EDH Error on Input
You can enable or disable this alarm. This alarm is active with CRC error
for the Active Picture
FF_EDH Error on Input
You can enable or disable this alarm. This alarm is active with CRC error
for the Full Field
Software Upgrade Failure
Software upgrade failed due to hardware
Other Trafic On Port
Other traffic on the port
Duplicate Sgid
The alarm is triggered by a primary device if another primary device in the
group is detected with same SGID.
For 1:1 scheme the SGID is not user configurable so this alarm is triggered
if more than one primary is configured with the same group ID.
Solution:
Check the other primary devices and find the one with the same Group ID
and same SGID.
For 1:1, find two primary devices with the same GID.
Redundancy Mode Mismatc
Redundancy mode mismatch.
Backup Device is Active
The alarm is triggered by a backup device when it is active.
Solution:
Swap between the primary and the backup.
Primary Device is not Active
The alarm is triggered by a primary device when it is inactive.
Solution:
Check what caused the primary to be inactive, fix the problem then switch
back.
Fail to Sync Configuration
This alarm is triggered by a backup device when it fails to get the primary’s
configuration.
Solution:
Check why the backup can’t get the configuration. It can be due to a
primary problem, primary connectivity (the sync can only be on the
management network) or backup connectivity.
No Available Backup
This alarm is triggered by a primary Ellipse when there is no available
backup Ellipse in the same group with a valid configuration and without
DRT.
Solution:
Check the backup device for
■
Connectivity
■
A valid configuration
If it is already active