Chapter 10 Unit Configuration
© 2013 Harmonic Inc. Harmonic All rights reserved.
285
Ellipse 3000 Release 3.0, Rev. B
SNMP Traps Sub-Menu
10.4.1.2
IP Address
The
IP Address
parameter sets the trap-host IP address.
The available value is of IP address type: xxx.xxx.xxx.xxx.
Front Panel
To set the
IP Address
parameter on the front panel:
❖
Navigate
Root > Configuration > Unit > SNMP Traps > Traps Destinations List > [Trap
Name] > IP Address
.
Web Manager
To set the
IP Address
parameter in the Web Manager:
❖
Select
Unit > SNMP Traps > [trap entry name]
.
10.4.1.3
UDP Port
The
UDP Port
parameter sets the trap-host UDP port.
The range is 0 to 65535.
Front Panel
To set the
UDP Port
parameter on the front panel:
❖
Navigate
Root > Configuration > Unit > SNMP Traps > Traps Destinations List > [Trap
Name] > UDP Port
.
Web Manager
To set the
UDP Port
parameter in the Web Manager:
❖
Select
Unit > SNMP Traps > [trap entry name]
.
IP Address
100.001.001.010
UDP Port
00162
<00000 - +65535>