Chapter 9 Input Interface Configuration
© 2013 Harmonic Inc. Harmonic All rights reserved.
250
Ellipse 3000 Release 3.0, Rev. B
IP Input Menu (MPE input)
9.3.1.2
MPE PID (IP Input / MPE)
The PID parameter sets the MPE PID value.
Front Panel
To access the PID menu on the front panel:
❖
Navigate
Root > Configuration > Inputs > IP Input > MPE > PID
.
The range is 32 to 8190.
Web Manager
To set the MPE PID in the Web Manager:
❖
Select
Inputs > IP Input > MPE
.
9.3.1.3
MPE Rate (IP Input / MPE)
The Rate parameter sets the MPE rate value (in bps).
Front Panel
To access the Rate menu on the front panel:
❖
Navigate
Root > Configuration > Inputs > IP Input > MPE > Rate
.
The range is 00000001 to 20000000 bps.
Web Manager
To set the MPE rate in the Web Manager:
❖
Select
Inputs > IP Input > MPE
.
PID
138
<+0032 - +8190>
Rate
+01000000 [bps]
<00000001 - +20000000>