308925
15
Installation
Option 3, for continuous applications when
reservoirs are filled manually:
Install additional
circulation pumps to create a loop from the reser-
voirs, through the circulation pumps, through the
heaters, and back to the reservoirs. See Fig. 7. Fill
the reservoirs manually. Set the heaters to the
desired temperature and circulate the fluid using
the circulation pumps. When the fluid temperature
in the reservoirs reaches the desired level, begin
spraying. Add material as required. Fluid will
continue to circulate. With this option, continuous
spraying is possible.
Reservoir
Proportioner
Fluid Cabinet
Mix Manifold
Gun
Pump
Heater
Circulation
Pump
8685A
Fig. 7
NOTE: This configuration is used both on the
A Component and on the B Component sides.
Proportioner
Fluid Cabinet
Mix Manifold
Gun
Pump
Heater
Fig. 8
NOTE: This configuration is used on the basic
units (when reservoirs are not used).
Содержание SuperCat 232721
Страница 23: ...308925 23 Notes...
Страница 82: ...308925 82 Service 8753A Fig 100 A B 497 446 385 361 381 442 363 311 312 363 442 361 381 385 424 469 458...
Страница 98: ...308925 98 Parts 8789A 8337A 53a 53b 53c 54a 54b 54c 54d 54e 56 54f 70 50 14 15 10 12 13 64 1 69 31...
Страница 111: ...308925 111 Notes...
Страница 112: ...308925 112 Dimensions 8787A 42 in 1067 mm 66 in 1676 mm 74 in 1880 mm...