308925
25
Control Overview
System Schematic Panel
Refer to Fig. 19. The System Schematic Panel is a
representation of the SuperCat system. The 17 lights
indicate active operator keypad functions (blinking
green light), pump activation (constant green light),
and alarm conditions (constant red light). The blinking
lights provide a quick reference as to what information
the keypad is displaying.
There are four keys on the schematic that can be
pressed in Manual Mode to activate the Premier pump,
solvent pump, and if used, feed pumps A and B.
The solvent pump key is the one pump key that is
operational in both Manual and Spray Modes.
The solvent pump will run until the amount of
solvent entered in Setup Mode is supplied.
In Manual Mode, the feed pumps run until the fluid
reaches the full level sensor or the feed pump time
limit has elapsed.
In Manual Mode, the Premier pump runs as long as
the Premier pump key is held and stops when the
key is released.
Setup Mode
To switch to Setup Mode, you must first be in
Manual
Mode
. See page 24. Then touch the key (EE) to the
setup contacts (TT) on the front of the control enclo-
sure. See Fig. 17.
EE
Fig. 17
TT
There are seven levels of setup. The active setup level
number will appear in the left most digit position on the
control display. Level 1 appears when Setup Mode is
initially accessed. See Fig. 18.
NOTE:
See the Operation Manual 308875 for a
Key-
pad Quick Reference
table for the setup functions.
Fig. 18
Setup Level
Содержание SuperCat 232721
Страница 23: ...308925 23 Notes...
Страница 82: ...308925 82 Service 8753A Fig 100 A B 497 446 385 361 381 442 363 311 312 363 442 361 381 385 424 469 458...
Страница 98: ...308925 98 Parts 8789A 8337A 53a 53b 53c 54a 54b 54c 54d 54e 56 54f 70 50 14 15 10 12 13 64 1 69 31...
Страница 111: ...308925 111 Notes...
Страница 112: ...308925 112 Dimensions 8787A 42 in 1067 mm 66 in 1676 mm 74 in 1880 mm...