308925
14
Installation
b.
Option 2, for continuous applications
when reservoirs are filled manually:
In this
configuration, the maximum working pressure
of the proportioner must be derated to 4000
psi (27.6 MPa, 276 bar). See the
Warning
at
right. Reduce the maximum working pressure
setting in the SuperCat electronics to 4000 psi
(27.6 MPa, 276 bar) or lower (see page 41).
Install the heaters on the fluid lines between the
proportioner pump and the fluid cabinet. See Fig.
6. Also, pressure relief valves are required be-
tween the proportioner pump and the heaters, to
protect against overpressurization should the
heaters become plugged.
Fill the reservoirs manually. Set the heaters to the
desired temperature and begin spraying. With this
option, continuous spraying is possible.
WARNING
COMPONENT RUPTURE HAZARD
Do not exceed the heater’s maximum
fluid working pressure of 4000 psi (27.6
MPa, 276 bar).
Install Part No. 237074 Pressure Relief Valves on
the fluid lines between the proportioner pump and
the fluid heaters, to prevent overpressurization
should the heaters become plugged.
Reservoir
Proportioner
Fluid Cabinet
Mix Manifold
Gun
Heater
Pump
Pressure Relief
Valve
8684A
Fig. 6
NOTE: This configuration is used both on the
A Component and on the B Component sides.
Recirculation
Line
Содержание SuperCat 232721
Страница 23: ...308925 23 Notes...
Страница 82: ...308925 82 Service 8753A Fig 100 A B 497 446 385 361 381 442 363 311 312 363 442 361 381 385 424 469 458...
Страница 98: ...308925 98 Parts 8789A 8337A 53a 53b 53c 54a 54b 54c 54d 54e 56 54f 70 50 14 15 10 12 13 64 1 69 31...
Страница 111: ...308925 111 Notes...
Страница 112: ...308925 112 Dimensions 8787A 42 in 1067 mm 66 in 1676 mm 74 in 1880 mm...