308925
11
Installation
1. Connect the main air line.
NOTE:
See Fig. 1 for all installation steps except
where otherwise directed.
Connect the main air line to the 1 in. npsm(f) inlet
of the air line filter (79) at the back of the cabinet.
See Fig. 3.
The air supply at the proportioner must be a mini-
mum of 100 psi (0.7 MPa, 7 bar) and 150 scfm
(4.2 m
3
/min.).
A minimum 1 in. (25.4 mm) I.D. hose is recom-
mended.
8806A
Fig. 3
79
Main Air Line
2.
Optional: Install 241157 Heater Kit
NOTE:
Packages 232713 through 232724 are
shipped with the 241157 Heater Kit and two Viscon
HP Fluid Heaters installed.
Kit No. 241157 is available to convert an unheated
SuperCat proportioner to the standard heated
system described on page 12. The kit includes
necessary parts to install two Viscon HP
fluid
heaters on the SuperCat. Refer to manual 308914
for installation instructions.
Viscon HP heaters and feed pumps are not in-
cluded with the kit and must be ordered separately.
The heaters are available in four voltages. Specify
which voltage you desire.
Model 245863 Viscon HP Heater
(240 V, single-phase, 16.7 A)
Model 245864 Viscon HP Heater
(480 V, single-phase, 8.30 A)
Model 245862 Viscon HP Heater (Asia)
(200 V, single-phase, 20.0 A)
WARNING
FIRE, EXPLOSION, AND ELECTRIC
SHOCK HAZARD
The Viscon HP Heaters must be
installed by a qualified electrician in
compliance with all state and local codes
and regulations, to reduce the risk of
electric shock or other serious injury
during installation or operation.
When installing in a flammable atmo-
sphere (hazardous location) refer to
Article 500 of the US National Electric Code or
other applicable agency standards to plan the
work.
Refer to the Viscon HP Heater manual (supplied
with the heater) for information on heater power
supply requirements.
Do not
plug in or unplug a power cord in any area
containing flammable fluids or fumes, to avoid fire
or explosion resulting in serious injury.
Do not
put flammable materials and debris on or
near the heaters. Keep the work area clean.
WARNING
COMPONENT RUPTURE HAZARD
Heat causes fluid to expand. If the
heated fluid is trapped with nowhere to
expand, it can cause component rupture.
Be sure
to keep the heated fluid circulating (open
the recirculation valves).
Do not
install a fluid
shutoff device between the heater and the gun.
Содержание SuperCat 232721
Страница 23: ...308925 23 Notes...
Страница 82: ...308925 82 Service 8753A Fig 100 A B 497 446 385 361 381 442 363 311 312 363 442 361 381 385 424 469 458...
Страница 98: ...308925 98 Parts 8789A 8337A 53a 53b 53c 54a 54b 54c 54d 54e 56 54f 70 50 14 15 10 12 13 64 1 69 31...
Страница 111: ...308925 111 Notes...
Страница 112: ...308925 112 Dimensions 8787A 42 in 1067 mm 66 in 1676 mm 74 in 1880 mm...