308925
33
Manual or Spray Mode
Work Life Time
CAUTION
A backup system for tracking how long mixed mate-
rial has been in the system is imperative. Do not rely
on the work life time alarm alone.
When key 7 is pressed to display the remaining work
life time, the key 7 light turns green, and the schematic
work life time light blinks. See Fig. 34 and 35.
If the work life time that was entered in setup is
exceeded, the Work Life Time light will turn red and an
alarm will sound.
NOTE:
The work life timer starts counting when the
Premier pump stops cycling. The timer resets to zero
after the Premier cycles again. Since the system does
not measure volume, there are instances where the
material work life time could expire without an alarm
occurring. For example, when the proportioner is set to
recirculate, the work life timer will be reset even though
mixed material has not moved from the lines.
NOTE:
The work life time alarm may be disabled if
desired, by setting the work life timer to 0 minutes. See
page 55.
Fig. 34
7
A
A
B
A
B
A/B
S
B
A B
A/B
S
A
B
A
B
Work Life Time
Fig. 35
Содержание SuperCat 232721
Страница 23: ...308925 23 Notes...
Страница 82: ...308925 82 Service 8753A Fig 100 A B 497 446 385 361 381 442 363 311 312 363 442 361 381 385 424 469 458...
Страница 98: ...308925 98 Parts 8789A 8337A 53a 53b 53c 54a 54b 54c 54d 54e 56 54f 70 50 14 15 10 12 13 64 1 69 31...
Страница 111: ...308925 111 Notes...
Страница 112: ...308925 112 Dimensions 8787A 42 in 1067 mm 66 in 1676 mm 74 in 1880 mm...