Care of the System
WARNING
INJECTION HAZARD
To reduce the risk of serious injury,
follow the
Pressure Relief Procedure
on page 21 whenever you are instructed
to relieve the pressure.
CAUTION
Be sure to label all fluid path parts “component A” or
“component B”. Doing so prevents interchanging A
and B parts, which will contaminate the materials and
the fluid path through the equipment.
Color-coded chemically resistant tape may be used
to label the parts. Use Part No. 070540 blue for
component A, 070541 green for component B,
070542 red for mixed material, and 070543 white for
solvent.
Clean the Reservoir Outlet Filters
Check the reservoir outlet filters (54)
weekly
. If you
have the optional low pressure sensor, a red light on
the low pressure indicator at reservoir A or B will
indicate when the filter is clogged. See Fig. 94.
To remove the filters for cleaning:
1.
Follow the
Pressure Relief Procedure
on page 21.
2.
Close the reservoir ball valves (56).
3.
Disconnect the clamps (70) and remove the com-
ponent A and B suction hoses (64).
4.
Disconnect the wire from the low pressure sen-
sors, if present.
5.
Turn the filters and remove them. Disassemble the
filters.
6.
Clean the filter element (54e) and the filter bowl
(54a) with compatible solvent.
7.
Reassemble the filters. Be sure the lips of the
u-cup (54d) face up.
8.
Reinstall the filters. Reconnect the sensor wires (if
present) and suction hoses. Open the ball valves
(56).
8337A–part
Fig. 94
1
56
70
64
54e
54a
54d
1
Lips face up.
69
Содержание SuperCat 232721
Страница 23: ...308925 23 Notes...
Страница 82: ...308925 82 Service 8753A Fig 100 A B 497 446 385 361 381 442 363 311 312 363 442 361 381 385 424 469 458...
Страница 98: ...308925 98 Parts 8789A 8337A 53a 53b 53c 54a 54b 54c 54d 54e 56 54f 70 50 14 15 10 12 13 64 1 69 31...
Страница 111: ...308925 111 Notes...
Страница 112: ...308925 112 Dimensions 8787A 42 in 1067 mm 66 in 1676 mm 74 in 1880 mm...