308925
90
Service
Replacing the Sensors
High and Low Level Sensors
1.
Follow the
Pressure Relief Procedure
on page 21.
2.
Disconnect the level sensor assembly (46) con-
nector from its mating connector. See Fig. 108.
3.
Loosen the jam nut and unscrew the level sensor
assembly (46) from the sensor housing (47). Install
the new sensor assembly. Tighten the sensor until
it bottoms out, then tighten the jam nut.
4.
Connect the sensor assembly to the correctly
labeled mating connector (CA).
Fig. 108
47
46
CA
8349A
Temperature Limit Sensors
1.
Drain the reservoirs completely.
2.
Disconnect the level sensor assembly (513) con-
nector from its mating connector (CA).
3.
Remove the sensor assembly (513) from the
reservoir. Install the new sensor assembly.
4.
Connect the appropriate labeled connector to the
sensor.
8795A
Fig. 109
513
CA