Material Usage Display Check (pump cycle counter)
Problem
Operating Condition
Cause/Solution
Premier or solvent pump usage
display value does not change
In manual or spray mode
Visually check wire connections.
Check the resistance across the
sensor, while moving a strong mag-
net in front of the sensor. The reading
should be less than 0.1 ohms when a
magnet is in front of the sensor and
have no reading when there is no
magnet.
Check position of sensor.
Replace sensor if faulty. See
Service
on page 93.
Replace circuit board. See
Service
on page 87.