308925
86
Service
Removing the Mix Manifold for Service
1.
Flush the mix manifold, using the solvent pump, as
frequently during the day as necessary to avoid
exceeding the work-life limit of the material being
pumped.
2.
Clean the static mixer weekly. Refer to page 78.
3.
Follow the
Pressure Relief Procedure
on page 21.
4.
Refer to the CAUTION on page 80. Label the
component A and B hoses and remove them from
the manifold inlet fittings.
5.
Loosen the knob (K) and lift the mix manifold panel
off the hanger bracket (N), using the handles (P).
6.
Refer to the mix manifold manual 308858, sup-
plied, for service.
8344A–part
Fig. 104
P
N
K
Fig. 105
8383A
Gauge Port
Gauge Port
Service
Port
Service
Port