308925
85
Service
Removing the Solvent Pump for Service
1.
Stop the pump at the bottom of its stroke.
2.
Follow the
Pressure Relief Procedure
on page 21.
3.
Disconnect the air line from the solvent pump (89).
4.
Refer to the CAUTION on page 80. Label the
solvent pump (89), suction kit (610), and fluid hose
(59) with white tape, for reference when reassem-
bling. Remove the suction kit and fluid hose from
the solvent pump.
To service the displacement pump (D):
5.
Remove the lower cotter pin (C) and tie rod nuts
(N), then unscrew the displacement rod (R) from
the air motor adapter (A). Inspect the o-ring (B).
See Fig. 103.
6.
Refer to manual 307619 to service the displace-
ment pump.
7.
Reinstall in the reverse order.
To service the air motor (M):
8.
Disconnect the cycle counter sensor (607) from its
mating connector. Unscrew the cycle counter
sensor housing (622) from the air motor port.
9.
Remove the cable strap (620) and magnet (621)
from the solvent pump.
10. Remove the screws (623) and washers (624).
Remove the motor from its mounting bracket.
11. Disconnect the displacement pump (D) as ex-
plained above, if you have not already done so.
12. Refer to manual 306982 to service the President
air motor.
13. Reinstall in the reverse order.
8354A
Fig. 103
607
622
620
621
623
624
C
N
R
A
D
B
M
Содержание SuperCat 232721
Страница 23: ...308925 23 Notes...
Страница 82: ...308925 82 Service 8753A Fig 100 A B 497 446 385 361 381 442 363 311 312 363 442 361 381 385 424 469 458...
Страница 98: ...308925 98 Parts 8789A 8337A 53a 53b 53c 54a 54b 54c 54d 54e 56 54f 70 50 14 15 10 12 13 64 1 69 31...
Страница 111: ...308925 111 Notes...