manualshive.com logo in svg
background image

 

 

 

2TLC172117M0201 Rev.E  

ORIGINAL INSTRUCTIONS 

 

new.abb.com/low-voltage/products/safety-products 

 

  

SAFET Y PRODUCTS 

Tina 1A Blanking plug 

Product Manual 

 

 
 
 
 
 
 
 
 

 

 

 

Содержание Tina 1A

Страница 1: ...2TLC172117M0201 Rev E ORIGINAL INSTRUCTIONS new abb com low voltage products safety products SAFETY PRODUCTS Tina 1A Blanking plug Product Manual...

Страница 2: ...se uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad systems av...

Страница 3: ...s 5 3 Product description 6 4 Installation 7 4 1 Installation precautions 7 4 2 Testing safety functions 7 5 Connections 8 5 1 Connection examples 8 6 Functions 9 6 1 LED indications 9 6 2 Information...

Страница 4: ...umed that the reader of this document has knowledge of the following Basic knowledge of ABB safety products Knowledge of machine safety 1 4 Special notes Pay attention to special notes in the document...

Страница 5: ...ions standards and the Machinery directive Warning Failure to comply with instructions operation that is not in accordance with the use prescribed in the instructions improper installation or handling...

Страница 6: ...nection blocks Tina 4A or Tina 8A where Tina 1A is used as a blanking plug in unused M12 connections The Tina 1A blanking plug is intended for use in safety circuits in accordance with EN 60204 1 Warn...

Страница 7: ...ons shall be tested before starting up the system 4 2 Testing safety functions After each step the status of the input can be read on the monitoring device Steps for testing LED indication DYNlink sig...

Страница 8: ...ons M12 5 pole male connector A coded 1 24 VDC 2 DYNlink signal input 3 0 VDC 4 DYNlink signal output 5 Information output 5 1 Connection examples Caution All cable colors according to ABB standard ca...

Страница 9: ...Green DYNlink input signal OK Green red flashing DYNlink input open or 0 VDC Interrupted before this unit 6 2 Information output signal attributes Information output is toggling with a nominal freque...

Страница 10: ...tested regularly at least once every year to confirm that all the safety functions are working properly EN 62061 2005 A1 2013 A2 2015 EN ISO 13849 1 2015 Warning In case of breakdown or damage to the...

Страница 11: ...input Check if there is 24 VDC on DYNlink signal input If yes check cable connections or the unit before No LED light Loss of power supply Check 24 VDC 0 VDC power supply Green but no DYNlink output...

Страница 12: ...2TLC172117M0201 Rev E 12 9 Dimensions All dimensions are in mm...

Страница 13: ...VDC 15 25 Total current consumption Maximum 25 mARMS Note Total current consumption is the internal supply current when there is no information output current Valid over the operating voltage and ambi...

Страница 14: ...10 EN 62061 2005 Cor 2010 A1 2013 A2 2015 EN ISO 13849 1 2015 EN 60204 1 2018 IEC EN 61508 1 7 SIL3 PFHD 4 50 10 9 EN 62061 SIL3 EN ISO 13849 1 PL e category 4 Certificates T V Nord cCSAus Information...

Страница 15: ...2TLC172117M0201 Rev E 15 11 Declaration of conformity EC Declaration of conformity...

Страница 16: ...2TLC172117M0201 Rev E 16 UK Declaration of conformity...

Отзывы: