background image

 

 
2TLC172117M0201 Rev.E

 

2

 

 

Read and understand this document 

 

Please read and understand this document before using the products. Please consult ABB 
with any questions or comments.

 

Suitability for use  

ABB shall not be responsible for conformity with any standards, codes, or regulations that 
apply to the combination of products in the customer’s application or use of the product. 
Third party certificates for the products are available at https://new.abb.com/low-
voltage/products/safety-products. This information by itself is not sufficient for a complete 
determination of the suitability of the products in combination with the end product, 
machine, system, or other application or use.  
 
The following are some examples of applications for which particular attention must be 
given. This is not intended to be an exhaustive list of all possible uses of the products, nor is 
it intended to imply that the uses listed may be suitable for the products: 
 

 

Outdoor use, uses involving potential chemical contamination or electrical 
interference, or conditions or uses not described in this document. 

 

Nuclear energy control systems, combustion systems, railroad systems, aviation 
systems, medical equipment, amusement machines, vehicles, and installations 
subject to separate industry or government regulations. 

 

Systems, machines, and equipment that could present a risk to life or property. 

 
Please know and observe all prohibitions of use applicable to the products. 
 
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR 
PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO 
ADDRESS THE RISKS, AND THAT THE ABB PRODUCT IS PROPERLY RATED AND INSTALLED FOR 
THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.

 

 
Descriptions and examples show how the product works and can be used. It does not mean 
that it fulfills the requirements for all types of machines and processes. The buyer/user is 
responsible for installing and using the product according to applicable standards and 
regulations. We reserve the right to make changes to the product and the documentation 
without prior notice. 
 

 

Содержание Tina 1A

Страница 1: ...2TLC172117M0201 Rev E ORIGINAL INSTRUCTIONS new abb com low voltage products safety products SAFETY PRODUCTS Tina 1A Blanking plug Product Manual...

Страница 2: ...se uses involving potential chemical contamination or electrical interference or conditions or uses not described in this document Nuclear energy control systems combustion systems railroad systems av...

Страница 3: ...s 5 3 Product description 6 4 Installation 7 4 1 Installation precautions 7 4 2 Testing safety functions 7 5 Connections 8 5 1 Connection examples 8 6 Functions 9 6 1 LED indications 9 6 2 Information...

Страница 4: ...umed that the reader of this document has knowledge of the following Basic knowledge of ABB safety products Knowledge of machine safety 1 4 Special notes Pay attention to special notes in the document...

Страница 5: ...ions standards and the Machinery directive Warning Failure to comply with instructions operation that is not in accordance with the use prescribed in the instructions improper installation or handling...

Страница 6: ...nection blocks Tina 4A or Tina 8A where Tina 1A is used as a blanking plug in unused M12 connections The Tina 1A blanking plug is intended for use in safety circuits in accordance with EN 60204 1 Warn...

Страница 7: ...ons shall be tested before starting up the system 4 2 Testing safety functions After each step the status of the input can be read on the monitoring device Steps for testing LED indication DYNlink sig...

Страница 8: ...ons M12 5 pole male connector A coded 1 24 VDC 2 DYNlink signal input 3 0 VDC 4 DYNlink signal output 5 Information output 5 1 Connection examples Caution All cable colors according to ABB standard ca...

Страница 9: ...Green DYNlink input signal OK Green red flashing DYNlink input open or 0 VDC Interrupted before this unit 6 2 Information output signal attributes Information output is toggling with a nominal freque...

Страница 10: ...tested regularly at least once every year to confirm that all the safety functions are working properly EN 62061 2005 A1 2013 A2 2015 EN ISO 13849 1 2015 Warning In case of breakdown or damage to the...

Страница 11: ...input Check if there is 24 VDC on DYNlink signal input If yes check cable connections or the unit before No LED light Loss of power supply Check 24 VDC 0 VDC power supply Green but no DYNlink output...

Страница 12: ...2TLC172117M0201 Rev E 12 9 Dimensions All dimensions are in mm...

Страница 13: ...VDC 15 25 Total current consumption Maximum 25 mARMS Note Total current consumption is the internal supply current when there is no information output current Valid over the operating voltage and ambi...

Страница 14: ...10 EN 62061 2005 Cor 2010 A1 2013 A2 2015 EN ISO 13849 1 2015 EN 60204 1 2018 IEC EN 61508 1 7 SIL3 PFHD 4 50 10 9 EN 62061 SIL3 EN ISO 13849 1 PL e category 4 Certificates T V Nord cCSAus Information...

Страница 15: ...2TLC172117M0201 Rev E 15 11 Declaration of conformity EC Declaration of conformity...

Страница 16: ...2TLC172117M0201 Rev E 16 UK Declaration of conformity...

Отзывы: