8-1
Ch
ap. 8
SPECIFICA
T
IO
NS
Chapter 8 SPECIFICATIONS
8.1 Standard Model 1 (Basic Type)
8.1.1 Three-phase 230 V series
LD (Low Duty)-mode inverters for light load
Item Specifications
Type
(FRN_
_
_G1S-2U)
F50 001
002 003 005 007
010
015
020
025
030
040
050
060 075 100 125 150
Nominal applied motor
(HP)
*1
(Output rating)
0.5 1 2 3 5 7.5
10
15
20
25
30
40
50
60
75
100
125
150
Outp
ut r
a
tin
g
s
Rated capacity (kVA)
*2
1.2 2.0
3.2
4.4 7.2 11
13
18
24
30
35
46
58
72 86 113 138 165
Rated voltage (V)
*3
Three-phase 200 to 240 V (with AVR function)
Three-phase 200 to 230 V
(with AVR function)
Rated current (A)
*4
3 5 8 11
18
27
31.8
(29)
46.2
(42)
59.4
(55)
74.8
(68)
88
(80)
115
(107)
146
180 215 283 346 415
Overload capability
150%-1 min, 200%-3.0 s
120%-1 min
Inpu
t po
w
e
r Voltage, frequency
200 to 240 V, 50/60 Hz
200 to 220 V, 50 Hz,
200 to 230 V, 60 Hz
Allowable
voltage/frequency
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less)
*5
, Frequency: +5 to -5%
Required capacity
(with DCR) (kVA)]
*6
0.6 1.2
2.2 3.1 5.2 7.4
10.0
15.0
20.0
25.0
30.0
40.0
48.0
58.0
71.0
98.0 116 143
Braki
n
g
Torque (%)
*7
150%
100%
70%
15%
7
to
12%
Braking transistor
Built-in
–
Built-in braking resistor
Built-in
–
Braking time (s)
5 s
3.7 s
3.4 s
–
Duty
cycle
(%ED) 5 3 5 3 2
2.2 1.4
–
DC reactor (DCR)
Option
Standard
*8
Applicable safety
standards
UL508C, C22.2 No.14, EN61800-5-1:2007
Enclosure (IEC60529)
IP20, UL open type
IP00, UL open type
Cooling method
Natural cooling
Fan cooling
Weight / Mass
lbs (kg)
3.8
(1.7)
4.4
(2.0)
6.2
(2.8)
6.6
(3.0)
6.6
(3.0)
14
(6.5)
14
(6.5)
14
(6.5)
13
(5.8)
21
(9.5)
21
(9.5)
22
(10)
55
(25)
71
(32)
93
(42)
95
(43)
137
(62)
232
(105)
HD (High Duty)-mode inverters for heavy load
Item Specifications
Type (FRN_ _ _G1S-2U) F50
001
002
003
005
007
010
015
020
025
030
040
050
060
075
100
125
150
Nominal applied motor
(HP)
*1
(Output rating)
0.5 1 2 3 5 7.5
7.5
10
15
20
25
30
40
50 60 75 100
125
O
u
tpu
t
ra
ting
s
Rated capacity (kVA)
*2
1.2 2.0
3.2
4.4 7.2 11
11
15
20
25
30
36
47
58 72 86 113 138
Rated voltage (V)
*3
Three-phase 200 to 240 V (with AVR function)
Three-phase 200 to 230 V
(with AVR function)
Rated current (A)
3
5
8
11
18
27
27
37
49
63
76
90
119
146
180
215
283
346
Overload capability
150%-1 min, 200%-3.0 s
In
pu
t po
w
e
r Voltage, frequency
200 to 240 V, 50/60 Hz
200 to 220 V, 50 Hz,
200 to 230 V, 60 Hz
Allowable
voltage/frequency
Voltage: +10 to -15% (Interphase voltage unbalance: 2% or less)
*5
, Frequency: +5 to -5%
Required capacity
(with DCR) (kVA)
*6
0.6 1.2
2.2 3.1 5.2 7.4
7.4
10
15
20
25
30
40
48 58 71 98 116
B
ra
k
ing
Torque (%)
*7
150%
100%
20%
10 to 15%
Braking transistor
Built-in
–
Built-in braking resistor
Built-in
–
Braking time (s)
5 s
–
Duty cycle (%ED)
5
3
5
3
2
3
3
2
–
DC reactor (DCR)
Option
Standard *8
Applicable safety
standards
UL508C, C22.2 No.14, EN61800-5-1:2007
Enclosure (IEC60529)
IP20, UL open type
IP00, UL open type
Cooling method
Natural cooling
Fan cooling
Weight / Mass
lbs (kg)
3.8
(1.7)
4.4
(2.0)
6.2
(2.8)
6.6
(3.0)
6.6
(3.0)
14
(6.5)
14
(6.5)
14
(6.5)
13
(5.8)
21
(9.5)
21
(9.5)
22
(10)
55
(25)
71
(32)
93
(42)
95
(43)
137
(62)
232
(105)
*1 US-4P standard induction motor
*2 Rated capacity is calculated assuming the rated output voltage as 230 V for 230 V series and 460 V for 460 V series.
*3 Output voltage cannot exceed the power supply voltage.
*4 To use the inverter with the carrier frequency of 3 kHz or more at the surrounding temperature of 40°C (104°F) or higher, manage the load so that the
current comes to be within the rated ones enclosed in parentheses ( ) in continuous running.
*
5
3)
-
61800
(IEC
67
×
(V)
voltage
average
phase
-
Three
(V)
voltage
Min.
-
(V)
voltage
Max.
(%)
unbalance
Voltage
=
If this value is 2 to 3%, use an optional AC reactor (ACR).
*6 Required when a DC reactor (DCR) is used.
*7 Average braking torque for the motor running alone, without external braking resistor. (It varies with the efficiency of the motor.)
*8 The FRN100G1S-2U or higher type comes with a DC reactor (DCR).