Note that, operating the inverter under the condition that the DC fan is locked for long time may shorten the life of
electrolytic capacitors on the PCBs due to local high temperature inside the inverter. Be sure to check with the
LIFE
signal
etc., and replace the broken fan as soon as possible.
Braking transistor error detection (Bit 6)
dba
(40 HP or below)
Upon detection of a built-in braking transistor error, this feature stops the inverter and displays an alarm
dba
. Set data of
this bit to "0" when the inverter does not use a braking transistor and there is no need of entering an alarm state.
Switch IP20/IP40 enclosure (Bit 7) (for basic type of inverters only)
Mounting an IP40 option to inverters of 40 HP or below enables them to conform to IP40. In such a case, switch Bit 7 to "1"
for the protection coordination.
For details, refer to the instruction manual of the IP40 option.
To set data of function code H98, assign the setting of each function to each bit and then convert the 8-bit binary to the
decimal number.
Refer to the assignment of each function to each bit and a conversion example below.
Bit
Function
Bit data = 0
Bit data = 1
Factory default
0
Lower the carrier frequency
automatically
Disable Enable 1:
Enable
1
Detect input phase loss
Continue to run
Enter alarm processing
1: Enter alarm
processing
2
Detect output phase loss
Continue to run
Enter alarm processing
0: Continue to run
3
Select life judgment threshold
of DC link bus capacitor
Factory default
User-defined setting 0:
Factory
default
4
Judge the life of DC link bus
capacitor
Disable Enable 1:
Enable
5
Detect DC fan lock
Enter alarm
processing
Continue to run
0: Enter alarm
processing
6
Detect braking transistor error
Continue to run
Enter alarm processing
1: Enter alarm
processing
7
Switch IP20/IP40 enclosure
IP20 IP40 0:
IP20
An example of conversion from binary to decimal (for the number configured by the factory default setting shown above)
Decimal = Bit 7
×
2
7
+ Bit 6
×
2
6
+ Bit 5
×
2
5
+ Bit 4
×
2
4
+ Bit 3
×
2
3
+ Bit 2
×
2
2
+ Bit 1
×
2
1
+ Bit 0
×
2
0
= Bit 7
×
128 + Bit 6
×
64 + Bit 5
×
32 + Bit 4
×
16 + Bit 3
×
8 + Bit 2
×
4 + Bit 1
×
2 + Bit 0
×
1
= 0
×
128 + 1
×
64 + 0
×
32 + 1
×
16 + 0
×
8 + 0
×
4 + 1
×
2 + 1
×
1
= 64 + 16 + 2 + 1
= 83