5-169
Configuration of function codes for each step
Step No.
Input 1
Input 2
Logic circuit
General-purpose
timer
Time setting Output
(Note)
Step 1
U01
U02
U03
U04
U05
SO01
Step 2
U06
U07
U08
U09
U10
SO02
Step 3
U11
U12
U13
U14
U15
SO03
Step 4
U16
U17
U18
U19
U20
SO04
Step 5
U21
U22
U23
U24
U25
SO05
Step 6
U26
U27
U28
U29
U30
SO06
Step 7
U31
U32
U33
U34
U35
SO07
Step 8
U36
U37
U38
U39
U40
SO08
Step 9
U41 U42
U43
U44
U45
SO09
Step 10
U46
U47
U48
U49
U50
SO10
(Note) These items shown in this column are output signals, not function codes.
Inputs 1 and 2 (U01, U02, etc.)
The following signals are available as input signals.
Data Selectable
Signals
0000 (1000)
General-purpose output signals
Same as the ones specified by E20), e.g.,
RUN
(Inverter running),
FAR
(Frequency (speed)
arrival signal),
FDT
(Frequency (speed) detected),
LU
(Undervoltage detected (Inverter
stopped)),
B/D
(Torque polarity detected)
Note:
27 (Universal DO) is not available.
|
0105 (1105)
2001 (3001)
Output of step 1
SO01
2002 (3002)
Output of step 2
SO02
2003 (3003)
Output of step 3
SO03
2004 (3004)
Output of step 4
SO04
2005 (3005)
Output of step 5
SO05
2006 (3006)
Output of step 6
SO06
2007 (3007)
Output of step 7
SO07
2008 (3008)
Output of step 8
SO08
2009 (3009)
Output of step 9
SO09
2010 (3010)
Output of step 10
SO10
4001 (5001)
Terminal [X1] input signal
X1
4002 (5002)
Terminal [X2] input signal
X2
4003 (5003)
Terminal [X3] input signal
X3
4004 (5004)
Terminal [X4] input signal
X4
4005 (5005)
Terminal [X5] input signal
X5
4006 (5006)
Terminal [X6] input signal
X6
4007 (5007)
Terminal [X7] input signal
X7
4010 (5010)
Terminal [FWD] input signal
FWD
4011 (5011)
Terminal [REV] input signal
REV
6000 (7000)
Final run command
FL_RUN
(ON when "frequency command
≠
0" and a run command is given)
6001 (7001)
Final FWD run command
FL_FWD
(ON when "frequency command
≠
0" and a run forward command is given)
6002 (7002)
Final REV run command
FL_REV
(ON when "frequency command
≠
0" and a run reverse command is given)
6003 (7003)
During acceleration
DACC
(ON during acceleration)
6004 (7004)
During deceleration
DDEC
(ON during deceleration)