5-20
Ch
ap
. 5
FUNCTION C
O
DES
F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
r codes: Motor 4 Parameters
Code Name
Data
setting
range
Ch
an
ge
wh
e
n
run
ni
ng
Data c
op
yin
g
Default
setting
Drive control
Refer
to
page:
V/f
PG
V/f
w/o
PG
w/
PG
Torque
control
r01 Maximum Frequency 4
25.0 to 500.0 Hz
N Y 60.0
Y
Y
Y
Y Y
―
r02 Base Frequency 4
25.0 to 500.0 Hz
N Y 60.0
Y
Y
Y
Y Y
r03 Rated Voltage at Base Frequency 4
0: Output a voltage in proportion to input voltage
80 to 240: Output an AVR-controlled voltage
(for 230 V series)
160 to 500: Output an AVR-controlled voltage
(for 460 V series)
N Y2
230
460
Y Y Y Y Y
r04 Maximum Output Voltage 4
80 to 240: Output an AVR-controlled voltage
(for 230 V series)
160 to 500: Output an AVR-controlled voltage
(for 460 V series)
N Y2
230
460
Y Y N N Y
r05 Torque Boost 4
0.0% to 20.0%
(percentage with respect to "r03: Rated Voltage at Base
Frequency 4")
Y Y 0.0 Y
Y
N
N N
r06 Electronic
Thermal
Overload
Protection for Motor 4
(Select
motor
characteristics)
1: For a general-purpose motor with shaft-driven cooling
fan
2: For an inverter-driven motor, non-ventilated motor, or
motor with separately powered cooling fan
Y Y 1 Y
Y
Y
Y Y
r07
(Overload detection level) 0.00: Disable
1% to 135% of the rated current (allowable continuous drive
current) of the motor
Y Y1
Y2
*2 Y Y Y Y Y
r08
(Thermal time constant) 0.5 to 75.0 min
Y Y *3 Y
Y
Y
Y Y
r09 DC Braking 4
(Braking
starting
frequency)
0.0 to 60.0 Hz
Y Y 0.0 Y
Y
Y
Y N
r10
(Braking level) 0% to 80% (LD/MD mode)*4, 0% to 100% (HD mode)
Y Y 0 Y
Y
Y
Y N
r11
(Braking time) 0.00: Disable; 0.01 to 30.00 s
Y Y 0.00
Y
Y
Y
Y N
r12 Starting Frequency 4
0.0 to 60.0 Hz
Y Y 0.5 Y
Y
Y
Y N
r13 Load
Selection/
Auto Torque Boost/
Auto Energy Saving Operation 4
0: Variable torque load
1: Constant torque load
2: Auto-torque boost
3: Auto-energy saving operation
(Variable torque load during ACC/DEC)
4: Auto-energy saving operation
(Constant torque load during ACC/DEC)
5: Auto-energy saving operation
(Auto-torque boost during ACC/DEC)
N Y 1 Y
Y
N
Y N
r14 Drive Control Selection 4
0: V/f control with slip compensation inactive
1: Dynamic torque vector control
2: V/f control with slip compensation active
3: V/f control with speed sensor
4: Dynamic torque vector control with speed sensor
5: Vector control without speed sensor
6: Vector control with speed sensor
N Y 0 Y
Y
Y
Y Y
r15 Motor 4
(No. of poles) 2 to 22 poles
N Y1
Y2
4 Y Y Y Y Y
r16
(Rated capacity) 0.01 to 1000 kW (when r39 = 0, 2, 3 or 4)
0.01 to 1000 HP (when r39 = 1)
N Y1
Y2
*7 Y Y Y Y Y
r17
(Rated current) 0.00 to 2000 A
N Y1
Y2
*7 Y Y Y Y Y
r18
(Auto-tuning) 0: Disable
1: Tune while the motor stops. (%R1, %X and rated slip
frequency)
2: Tune while the motor is rotating under V/f control
(%R1, %X, rated slip frequency, no-load current,
magnetic saturation factors 1 to 5, and magnetic
saturation extension factors "a" to "c")
3: Tune while the motor is rotating under vector control
(%R1, %X, rated slip frequency, no-load current,
magnetic saturation factors 1 to 5, and magnetic
saturation extension factors "a" to "c." Available when
the vector control is enabled.)
N N 0 Y
Y
Y
Y Y
r19
(Online tuning) 0: Disable 1: Enable
Y Y 0 Y
N
N
N N
r20
(No-load current) 0.00 to 2000 A
N Y1
Y2
*7 Y Y Y Y Y
r21
(%R1) 0.00%
to
50.00%
Y Y1
Y2
*7 Y Y Y Y Y
r22
(%X) 0.00%
to
50.00%
Y Y1
Y2
*7 Y Y Y Y Y
r23 (Slip compensation gain for driving) 0.0% to 200.0%
Y*
Y 100.0 Y Y Y Y N
r24 (Slip compensation response time) 0.01 to 10.00 s
Y Y1
Y2 0.12 Y Y N N N
r25 (Slip compensation gain for braking) 0.0% to 200.0%
Y*
Y 100.0 Y Y Y Y N
r26
(Rated slip frequency) 0.00 to 15.00 Hz
N Y1
Y2
*7 Y Y Y Y N
r27
(Iron loss factor 1) 0.00% to 20.00%
Y Y1
Y2
*7 Y Y Y Y Y
*2 The motor rated current is automatically set. See Table B (P03/A17/b17/r17).
*3 5.0 min for inverters of 40 HP or below; 10.0 min for those of 50 HP or above
*4 0% to 100% for inverters of 7.5 HP or below
*7 The motor parameters are automatically set, depending upon the inverter's capacity. See Table B.