5-7
Code Name
Data
setting
range
Ch
ange wh
e
n
ru
nning
Dat
a
cop
yi
ng
Default
setting
Drive control
Refer
to
page:
V/f
PG
V/f
w/o
PG
w/
PG
Torque
control
E10 Acceleration Time 2
0.00 to 6000 s
Note: Entering 0.00 cancels the acceleration time,
requiring external soft-start and -stop.
Y Y
*1 Y
Y
Y
Y N 5-45
E11 Deceleration Time 2
Y Y
*1 Y
Y
Y
Y N 5-90
E12 Acceleration Time 3
Y Y
*1 Y
Y
Y
Y N
E13 Deceleration Time 3
Y Y
*1 Y
Y
Y
Y N
E14 Acceleration Time 4
Y Y
*1 Y
Y
Y
Y N
E15 Deceleration Time 4
Y Y
*1 Y
Y
Y
Y N
E16 Torque Limiter 2-1
-300% to 300%; 999 (Disable)
Y Y
999
Y Y Y
Y Y 5-66
E17 Torque Limiter 2-2
-300% to 300%; 999 (Disable)
Y Y
999
Y Y Y
Y Y 5-90
Selecting function code data assigns the corresponding
function to terminals [Y1] to [Y5A/C] and [30A/B/C] as
listed below.
5-91
E20 Terminal [Y1] Function
0 (1000): Inverter running
(
RUN
)
N Y
0 Y
Y Y
Y Y
E21 Terminal [Y2] Function
1 (1001): Frequency (speed) arrival signal
(
FAR
)
N Y
1 Y
Y Y
Y N
E22 Terminal [Y3] Function
2 (1002): Frequency (speed) detected
(
FDT
)
N Y
2 Y
Y Y
Y Y
E23 Terminal [Y4] Function
3 (1003): Undervoltage detected (Inverter stopped) (
LU
)
N Y
7 Y
Y Y
Y Y
E24 Terminal [Y5A/C] Function
4 (1004): Torque polarity detected
(
B/D
)
5 (1005): Inverter output limiting
(
IOL
)
N Y
15 Y
Y Y
Y Y
E27 Terminal [30A/B/C] Function
N Y
99 Y
Y Y
Y Y
(Relay output)
6 (1006): Auto-restarting after momentary power
failure (
IPF
)
Y
Y
Y
Y
Y
7 (1007): Motor overload early warning
(
OL
)
Y
Y
Y
Y
Y
8 (1008): Keypad operation enabled
(
KP
)
Y
Y
Y
Y
Y
10 (1010): Inverter ready to run
(
RDY
)
Y
Y
Y
Y
Y
11:
Switch motor drive source between
commercial power and inverter output
(For MC on commercial line)
(
SW88
)
Y
Y
N
N
N
12:
Switch motor drive source between
commercial power and inverter output
(For secondary side)
(
SW52-2
)
Y
Y
N
N
N
13:
Switch motor drive source between
commercial power and inverter output
(For primary side)
(
SW52-1
)
Y
Y
N
N
N
15 (1015): Select
AX
terminal function
(For MC on primary side)
(
AX
)
Y
Y
Y
Y
Y
22 (1022): Inverter output limiting with delay
(
IOL2
)
Y
Y
Y
Y
Y
25 (1025): Cooling fan in operation
(
FAN
)
Y
Y
Y
Y
Y
26
(1026):
Auto-resetting
(
TRY
)
Y
Y
Y
Y
Y
27
(1027):
Universal
DO
(
U-DO
)
Y
Y
Y
Y
Y
28 (1028): Heat sink overheat early warning
(
OH
)
Y
Y
Y
Y
Y
29 (1029): Synchronization completed
(
SY
)
N
Y
N
Y
N
30
(1030):
Lifetime
alarm
(
LIFE
)
Y
Y
Y
Y
Y
31 (1031): Frequency (speed) detected 2
(
FDT2
)
Y
Y
Y
Y
Y
33 (1033): Reference loss detected
(
REF OFF
)
Y
Y
Y
Y
Y
35 (1035): Inverter output on
(
RUN2
)
Y
Y
Y
Y
Y
36 (1036): Overload prevention control
(
OLP
)
Y
Y
Y
Y
N
37 (1037): Current detected
(
ID
)
Y
Y
Y
Y
Y
38 (1038): Current detected 2
(
ID2
)
Y
Y
Y
Y
Y
39 (1039): Current detected 3
(
ID3
)
Y
Y
Y
Y
Y
41 (1041): Low current detected
(
IDL
)
Y
Y
Y
Y
Y
42 (1042): PID alarm
(
PID-ALM
)
Y
Y
Y
Y
N
43 (1043): Under PID control
(
PID-CTL
)
Y
Y
Y
Y
N
44 (1044): Motor stopped due to slow
flowrate under PID control
(
PID-STP
)
Y
Y
Y
Y
N
45 (1045): Low output torque detected
(
U-TL
)
Y
Y
Y
Y
Y
46 (1046): Torque detected 1
(
TD1
)
Y
Y
Y
Y
Y
47 (1047): Torque detected 2
(
TD2
)
Y
Y
Y
Y
Y
48 (1048): Motor 1 selected
(
SWM1
)
Y
Y
Y
Y
Y
49 (1049): Motor 2 selected
(
SWM2
)
Y
Y
Y
Y
Y
50 (1050): Motor 3 selected
(
SWM3
)
Y
Y
Y
Y
Y
51 (1051): Motor 4 selected
(
SWM4
)
Y
Y
Y
Y
Y
52 (1052): Running forward
(
FRUN
)
Y
Y
Y
Y
Y
53 (1053): Running reverse
(
RRUN
)
Y
Y
Y
Y
Y
54 (1054): In remote operation
(
RMT
)
Y
Y
Y
Y
Y
56 (1056): Motor overheat detected by thermistor
(
THM
)
Y
Y
Y
Y
Y
57
(1057):
Brake
signal
(
BRKS
)
Y
Y
Y
Y
N
58 (1058): Frequency (speed) detected 3
(
FDT3
)
Y
Y
Y
Y
Y
59 (1059): Terminal [C1] wire break
(
C1OFF
)
Y
Y
Y
Y
Y
*1 6.00 s for inverters of 40 HP or below; 20.00 s for those of 50 HP or above
Содержание FRENIC-MEGA
Страница 36: ...2 6 Unit inch mm Refer to Section 2 3 3 9...
Страница 208: ...5 89 Examples of Sequence Circuits 1 Standard sequence 2 Sequence with an emergency switching function...
Страница 356: ...MEMO...
Страница 358: ...Fuji Electric Co Ltd Fuji Electric Corp of America http www fujielectric com fecoa 2011 04 D11 D10...