5-12
F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
Ch
ap
. 5
FUNCTION C
O
DES
P codes: Motor 1 Parameters
Code Name
Data
setting
range
Ch
an
ge
wh
e
n
run
ni
ng
Data c
op
yin
g
Default
setting
Drive control
Refer
to
page:
V/f
PG
V/f
w/o
PG
w/
PG
Torque
control
P01 Motor 1
(No. of poles) 2 to 22 poles
N Y1
Y2
4 Y Y Y Y Y 5-111
P02
(Rated capacity) 0.01 to 1000 kW (when P99 = 0, 2, 3 or 4)
0.01 to 1000 HP (when P99 = 1)
N Y1
Y2
*7 Y Y Y Y Y
P03
(Rated current) 0.00 to 2000 A
N Y1
Y2
*7 Y Y Y Y Y
P04
(Auto-tuning) 0: Disable
1: Tune while the motor stops. (%R1, %X and rated slip
frequency)
2: Tune while the motor is rotating under V/f control
(%R1, %X, rated slip frequency, no-load current,
magnetic saturation factors 1 to 5, and magnetic
saturation extension factors "a" to "c")
3: Tune while the motor is rotating under vector control
(%R1, %X, rated slip frequency, no-load current,
magnetic saturation factors 1 to 5, and magnetic
saturation extension factors "a" to "c." Available when
the vector control is enabled.)
N N 0 Y
Y
Y
Y Y
5-112
P05
(Online tuning) 0: Disable 1: Enable
Y Y
0 Y N N N N 5-113
P06
(No-load current) 0.00 to 2000 A
N Y1
Y2
*7 Y Y Y Y Y
P07
(%R1) 0.00% to 50.00%
Y Y1
Y2
*7 Y Y Y Y Y
P08
(%X) 0.00% to 50.00%
Y Y1
Y2
*7 Y Y Y Y Y
P09 (Slip compensation gain for driving) 0.0% to 200.0%
Y*
Y 100.0 Y Y Y Y N 5-114
P10 (Slip compensation response time) 0.01 to 10.00 s
Y Y1
Y2 0.12 Y Y N N N
P11 (Slip compensation gain for braking) 0.0% to 200.0%
Y*
Y 100.0 Y Y Y Y N
P12
(Rated slip frequency) 0.00 to 15.00 Hz
N Y1
Y2
*7 Y Y Y Y N
P13
(Iron loss factor 1) 0.00% to 20.00%
Y Y1
Y2
*7 Y Y Y Y Y
P14
(Iron loss factor 2) 0.00% to 20.00%
Y Y1
Y2 0.00 Y Y Y Y Y
P15
(Iron loss factor 3) 0.00% to 20.00%
Y Y1
Y2 0.00 Y Y Y Y Y
P16
(Magnetic saturation factor 1) 0.0% to 300.0%
Y Y1
Y2
*7 Y Y Y Y Y
P17
(Magnetic saturation factor 2) 0.0% to 300.0%
Y Y1
Y2
*7 Y Y Y Y Y
P18
(Magnetic saturation factor 3) 0.0% to 300.0%
Y Y1
Y2
*7 Y Y Y Y Y
P19
(Magnetic saturation factor 4) 0.0% to 300.0%
Y Y1
Y2
*7 Y Y Y Y Y
P20
(Magnetic saturation factor 5) 0.0% to 300.0%
Y Y1
Y2
*7 Y Y Y Y Y
P21
(Magnetic saturation extension
factor
"a")
0.0% to 300.0%
Y Y1
Y2
*7 Y Y Y Y Y
P22
(Magnetic saturation extension
factor
"b")
0.0% to 300.0%
Y Y1
Y2
*7 Y Y Y Y Y
P23
(Magnetic saturation extension
factor
"c")
0.0% to 300.0%
Y Y1
Y2
*7 Y Y Y Y Y
P53
(%X correction factor 1) 0% to 300%
Y Y1
Y2
100 Y Y Y Y Y 5-115
P54
(%X correction factor 2) 0% to 300%
Y Y1
Y2
100 Y Y Y Y Y
P55 (Torque current under vector control) 0.00 to 2000 A
N Y1
Y2
*7 N N Y Y Y
P56
(Induced voltage factor under
vector
control)
50% to 100%
N Y1
Y2 85
(90)
*8
N N Y Y Y
P57 Reserved *
9
―
- - - -
-
-
- -
―
P99 Motor 1 Selection
0: Motor characteristics 0 (Fuji standard motors, 8-series)
1: Motor characteristics 1 (HP rating motors)
2: Motor characteristics 2 (Fuji motors exclusively designed
for vector control)
3: Motor characteristics 3 (Fuji standard motors, 6-series)
4: Other motors
N Y1
Y2
1 Y Y Y Y Y 5-115
The shaded function codes (
) are applicable to the quick setup.
*7 The motor parameters are automatically set, depending upon the inverter's capacity. See Table B.
*8 85% for inverters of 150 HP or less; 90% for those of 175 HP or above.
*9 Factory use. Do not access these function codes.