5-48
Ch
ap
. 5
FUNCTION C
O
DES
F codes
Curvilinear acceleration/deceleration
Acceleration/deceleration is linear below the base frequency (constant torque) but it slows down above the base frequency to
maintain a certain level of load factor (constant output).
This acceleration/deceleration pattern allows the motor to accelerate or decelerate with its maximum performance.
The figures at left show the acceleration characteristics.
Similar characteristics apply to the deceleration.
• If you choose S-curve acceleration/deceleration or curvilinear acceleration/deceleration in Acceleration/
Deceleration Pattern (H07), the actual acceleration/deceleration times are longer than the specified times.
• Specifying an improperly short acceleration/deceleration time may activate the current limiter, torque limiter, or
anti-regenerative control, resulting in a longer acceleration/deceleration time than the specified one.
F09 Torque
Boost
1
(Refer to F37.)