5-5
Code Name
Data
setting
range
Ch
ange wh
e
n
ru
nning
Da
ta
cop
yi
ng Default
setting
Drive control
Refer
to
page:
V/f
PG
V/f
w/o
PG
w/
PG
Torque
control
F43 Current Limiter
(Mode selection) 0: Disable (No current limiter works.)
1: Enable at constant speed (Disable during ACC/DEC)
2: Enable during ACC/constant speed operation
Y
Y
2
Y Y N N N 5-75
F44
(Level) 20% to 200% (The data is interpreted as the rated output
current of the inverter for 100%.)
Y
Y *5
Y
Y
N
N
N
F50 Electronic Thermal Overload
Protection for Braking Resistor
(Discharging
capability)
0 (Braking resistor built-in type), 1 to 9000 kWs,
OFF (Disable)
Y
Y1
Y2
*6 Y Y Y Y Y 5-76
F51
(Allowable average loss) 0.001 to 99.99 kW
Y
Y1
Y2 0.001 Y Y Y Y Y
F52
(Resistance) 0.01 to 999
Ω
Y
Y1
Y2
0.01 Y Y Y Y Y
F80 Switching between LD, MD and HD
drive modes
0: HD (High Duty) mode
1: LD (Low Duty) mode
2: MD (Medium Duty) mode
N
Y
1 Y Y Y Y Y 5-77
*5 160% for inverters of 7.5 HP or below; 130% for those of 10 HP or above
*6 0 for inverters of 15 HP or below; OFF for those of 20 HP or above
Содержание FRENIC-MEGA
Страница 36: ...2 6 Unit inch mm Refer to Section 2 3 3 9...
Страница 208: ...5 89 Examples of Sequence Circuits 1 Standard sequence 2 Sequence with an emergency switching function...
Страница 356: ...MEMO...
Страница 358: ...Fuji Electric Co Ltd Fuji Electric Corp of America http www fujielectric com fecoa 2011 04 D11 D10...