![Fuji Electric FRENIC-MEGA Скачать руководство пользователя страница 261](http://html1.mh-extra.com/html/fuji-electric/frenic-mega/frenic-mega_instruction-manual_2341853261.webp)
5-142
F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
Ch
ap
. 5
FUNCTION C
O
DES
[ 1 ] PID command with the
/
keys on the keypad (J02 = 0, factory default)
Configuring the PID command (PID process command or PID dancer position command) with the
and keys
(1) To enable PID process control, set function code J01 at "1" or "2."
To enable PID dancer control, set function code J01 at "3."
(2) Set function code J02 at "0" ( / keys on keypad).
(3) Set the LED monitor to something other than the speed monitor (E43 = 0) when the inverter is in Running mode.
In Programming or Alarm mode, the PID command cannot be modified with the and keys, so switch to
Running mode beforehand.
(4) Press the or key.
The 7-segment LED monitor displays the PID command and the LCD monitor displays the related information
including the operation guide, as shown below.
Example of PID Command Configuration Screen
On the LED monitor, the decimal point of the lowest digit is used to characterize what is displayed. The decimal
point of the lowest digit blinks when a PID command is displayed; the decimal point lights when a PID feedback
amount is displayed.
(5) To change the PID command, press the or key again. To save the new setting into the inverter's memory, press
the
key (when E64 = 1 (factory default)). When the power is turned ON next time, the new setting will be used as
an initial reference frequency.
In addition to saving with the
key described above, "Automatic saving when the main power is turned OFF" is also
possible (when E64 = 0).
•
Using the
/
keys on the keypad in conjunction with PID display coefficients (specified by E40 and
E41), you can specify 0 to 100% of the PID process command (±100% of the PID dancer position command) in
an easy-to-understand converted command format.
•
Even if multi-frequency is selected as a PID command (
SS4
or
SS8
= ON), setting the PID command with the
keypad is possible.
•
When function code J02 is set to any value other than "0," pressing the
or key displays, on the LED
monitor, the PID command currently selected, but cannot change the setting. The LCD monitor displays the
following.
The lowest digit blinks.
Means that the keypad command is effective.
Allowable range
Operation guide
Means that PID command 1 (analog
command) is effective.