5-26
F codes
E codes
C codes
P codes
H codes
A codes
b codes
r codes
J codes
d codes
U codes
y codes
Ch
ap
. 5
FUNCTION C
O
DES
Code Name
Data
setting
range
Ch
ange wh
e
n
ru
nnin
g
Dat
a
cop
yi
ng
Default
setting
Drive control
Refer
to
page:
V/f
PG
V/f
w/o
PG
w/
PG
Torque
control
84 (1084): Maintenance timer
(
MNT
)
Y Y Y Y Y 5-167
98
(1098):
Light
alarm
(
L-ALM
)
Y Y Y Y Y
99 (1099): Alarm output (for any alarm)
(
ALM
)
Y Y Y Y Y
101 (1101): Enable circuit failure detected
(
DECF
)
Y Y Y Y Y
102 (1102): Enable input OFF
(
EN OFF
)
Y Y Y Y Y
105 (1105): Braking transistor broken
(
DBAL
)
Y Y Y Y Y
2001 (3001): Output of step 1
(
SO01
)
Y Y Y Y Y
2002 (3002): Output of step 2
(
SO02
)
Y Y Y Y Y
2003 (3003): Output of step 3
(
SO03
)
Y Y Y Y Y
2004 (3004): Output of step 4
(
SO04
)
Y Y Y Y Y
2005 (3005): Output of step 5
(
SO05
)
Y Y Y Y Y
2006 (3006): Output of step 6
(
SO06
)
Y Y Y Y Y
2007 (3007): Output of step 7
(
SO07
)
Y Y Y Y Y
2008 (3008): Output of step 8
(
SO08
)
Y Y Y Y Y
2009 (3009): Output of step 9
(
SO09
)
Y Y Y Y Y
2010 (3010): Output of step 10
(
SO10
)
Y Y Y Y Y
4001 (5001): Terminal [X1] input signal
(
X1
)
Y Y Y Y Y
4002 (5002): Terminal [X2] input signal
(
X2
)
Y Y Y Y Y
4003 (5003): Terminal [X3] input signal
(
X3
)
Y Y Y Y Y
4004 (5004): Terminal [X4] input signal
(
X4
)
Y Y Y Y Y
4005 (5005): Terminal [X5] input signal
(
X5
)
Y Y Y Y Y
4006 (5006): Terminal [X6] input signal
(
X6
)
Y Y Y Y Y
4007 (5007): Terminal [X7] input signal
(
X7
)
Y Y Y Y Y
4010 (5010): Terminal [FWD] input signal
(
FWD
)
Y Y Y Y Y
4011 (5011): Terminal [REV] input signal
(
REV
)
Y Y Y Y Y
6000 (7000): Final run command
(
FL_RUN
)
Y Y Y Y Y
6001 (7001): Final FWD run command
(
FL_FWD
)
Y Y Y Y Y
6002 (7002): Final REV run command
(
FL_REV
)
Y Y Y Y Y
6003
(7003):
During
acceleration
(
DACC
)
Y Y Y Y Y
6004
(7004):
During
deceleration
(
DDEC
)
Y Y Y Y Y
6005 (7005): Under anti-regenerative control
(
REGA
)
Y Y Y Y Y
6006 (7006): Within dancer reference position (
DR_REF
)
Y Y Y Y Y
6007 (7007): Alarm factor presence
(
ALM_ACT
)
Setting the value in parentheses ( ) shown above assigns a
negative logic output to a terminal. (True if OFF.)
Y Y Y Y Y
U03
(Logic circuit) 0: No function assigned
1: Through General-purpose timer
2: General-purpose timer
3: ORing + General-purpose timer
4: General-purpose timer
5: Set priority flip-flop + General-purpose timer
6: Reset priority flip-flop + General-purpose timer
7: Rising edge de General-purpose timer
8: Falling edge de General-purpose timer
9: Rising and falling edge de General-purpose
timer
10: Input hold + General-purpose timer
11: Increment counter
12: Decrement counter
13: Timer with reset input
N Y 0 Y
Y
Y
Y Y
U04
(Type of timer) 0: No timer
1: On-delay
timer
2: Off-delay
timer
3: Pulse
4: Retriggerable
timer
5: Pulse
train
output
N Y 0 Y
Y
Y
Y Y
U05
(Timer) 0.00 to 600.00
N Y 0.00
Y
Y
Y
Y Y
U06 Customizable Logic:
(Input 1) See U01.
N Y 0
See
U01.
U07 Step 2
(Input 2) See U02.
N Y 0
See
U02.
U08
(Logic circuit) See U03.
N Y 0 Y
Y
Y
Y Y
U09
(Type of timer) See U04.
N Y 0 Y
Y
Y
Y Y
U10
(Timer) See U05.
N Y 0.00
Y
Y
Y
Y Y