![Fuji Electric FRENIC-MEGA Скачать руководство пользователя страница 142](http://html1.mh-extra.com/html/fuji-electric/frenic-mega/frenic-mega_instruction-manual_2341853142.webp)
5-23
d codes: Application Functions 2
Code Name
Data
setting
range
Ch
an
ge
wh
e
n
run
ni
ng
Data c
op
yin
g
Default
setting
Drive control
Refer
to
page:
V/f
PG
V/f
w/o
PG
w/
PG
Torque
control
d01 Speed Control 1
(Speed command filter)
0.000 to 5.000 s
Y Y 0.020 N Y Y Y N 5-159
d02
(Speed detection filter) 0.000 to 0.100 s
Y*
Y 0.005 N Y Y Y N
d03
P (Gain) 0.1 to 200.0 times
Y*
Y 10.0 N Y Y Y N
d04
I (Integral time) 0.001 to 9.999 s
Y*
Y 0.100 N Y Y Y N
d06
(Output filter) 0.000 to 0.100 s
Y Y 0.002 N Y Y Y N
d07 (Notch filter resonance frequency) 1 to 200 Hz
Y Y 200 N N N Y N 5-160
d08
(Notch filter attenuation level) 0 to 20 dB
Y Y
0 N N N Y N
d09 Speed Control (Jogging)
(Speed command filter)
0.000 to 5.000 s
Y Y 0.020 N Y Y Y N 5-159
5-160
d10
(Speed detection filter) 0.000 to 0.100 s
Y*
Y 0.005 N Y Y Y N
d11
P (Gain) 0.1 to 200.0 times
Y*
Y 10.0 N Y Y Y N
d12
I (Integral time) 0.001 to 9.999 s
Y*
Y 0.100 N Y Y Y N
d13
(Output filter) 0.000 to 0.100 s
Y Y 0.002 N Y Y Y N
d14 Feedback Input
(Pulse input format)
0: Pulse train sign/Pulse train input
1: Forward rotation pulse/Reverse rotation pulse
2: A/B phase with 90 degree phase shift
N Y 2 N
Y
N
Y Y
5-161
d15
(Encoder pulse resolution) 20 to 60000 pulses
N Y 1024
N
Y
N
Y Y
d16
(Pulse count factor 1) 1 to 9999
N Y 1 N
Y
N
Y Y
d17
(Pulse count factor 2) 1 to 9999
N Y 1 N
Y
N
Y Y
d21 Speed
Agreement/PG Error
(Hysteresis
width)
0.0% to 50.0%
Y Y 10.0 N Y Y Y N 5-162
d22
(Detection timer) 0.00 to 10.00 s
Y Y 0.50 N Y Y Y N
d23 PG Error Processing
0: Continue to run 1
1: Stop running with alarm 1
2: Stop running with alarm 2
3: Continue to run 2
4: Stop running with alarm 3
5: Stop running with alarm 4
N Y
2 N Y Y Y Y
d24 Zero Speed Control
0: Not permit at startup
1: Permit at startup
N Y 0 N
N
Y
Y N 5-59
5-163
d25 ASR Switching Time
0.000 to 1.000 s
Y Y 0.000 N Y Y Y Y 5-137
5-163
d32 Torque Control
(Speed limit 1) 0 to 110 %
Y Y 100 N
N
Y
Y Y
5-121
d33
(Speed limit 2) 0 to 110 %
Y Y 100 N
N
Y
Y Y
5-163
d41 Application-defined Control
0: Disable (Ordinary control)
N
Y
0
Y
Y
Y
Y
Y
5-163
1: Enable (Constant peripheral speed control)
N
Y
N
N
N
2: Enable (Simultaneous synchronization, without Z phase)
N
Y
N
Y
N
3: Enable (Standby synchronization)
N
Y
N
Y
N
4: Enable (Simultaneous synchronization, with Z phase)
N
Y
N
Y
N
d51 Reserved *
9
―
- - - -
-
-
- -
5-165
d52 Reserved *
9
―
- - - -
-
-
- -
d53 Reserved *
9
―
- - - -
-
-
- -
d54 Reserved *
9
―
- - - -
-
-
- -
d55 Reserved *
9
―
- - - -
-
-
- -
d59 Command (Pulse Rate Input)
(Pulse input format)
0: Pulse train sign/Pulse train input
1: Forward rotation pulse/Reverse rotation pulse
2: A/B phase with 90 degree phase shift
N Y 0 Y
Y
Y
Y Y 5-34
5-165
d60
(Encoder pulse resolution) 20 to 3600 pulses
N Y 1024 N Y N Y N 5-166
d61
(Filter time constant) 0.000 to 5.000 s
Y Y
0.005
Y
Y
Y
Y Y
5-165
d62
(Pulse count factor 1) 1 to 9999
N Y 1 Y
Y
Y
Y Y
d63
(Pulse count factor 2) 1 to 9999
N Y 1 Y
Y
Y
Y Y
d67 Starting Mode
(Auto search) 0: Disable
1: Enable (At restart after momentary power failure)
2: Enable (At restart after momentary power failure and at
normal start)
N Y
2 N N Y N Y 5-119
d68 Reserved *
9
―
- - - -
-
-
- -
5-165
d69 Reserved *
9
―
- - - -
-
-
- -
d70 Speed Control Limiter
0.00 to 100.00%
Y Y 100.00 N Y N Y N 5-166
*9 Factory use. Do not access these function codes.
Содержание FRENIC-MEGA
Страница 36: ...2 6 Unit inch mm Refer to Section 2 3 3 9...
Страница 208: ...5 89 Examples of Sequence Circuits 1 Standard sequence 2 Sequence with an emergency switching function...
Страница 356: ...MEMO...
Страница 358: ...Fuji Electric Co Ltd Fuji Electric Corp of America http www fujielectric com fecoa 2011 04 D11 D10...