Device alarm simulation
Diagnostic event category
Diagnostic event simulation
Parameter overview with brief description
Parameter
Prerequisite
Description
Selection / User
entry / User
interface
Factory setting
Assign simulation process variable
–
Select a process variable for
the simulation process that is
activated.
• Off
• Mass flow
• Volume flow
• Corrected volume
flow
• Density
• Reference density
• Temperature
• Concentration
• Target mass flow
• Carrier mass flow
Off
Process variable value
One of the following options is
selected in the
Assign
simulation process variable
parameter (→ 143):
• Mass flow
• Volume flow
• Corrected volume flow
• Density
• Reference density
• Temperature
• Concentration
• Target mass flow
• Carrier mass flow
Enter the simulation value for
the selected process variable.
Depends on the
process variable
selected
0
Status input simulation
–
Switch simulation of the status
input on and off.
• Off
• On
Off
Input signal level
In the
Status input simulation
parameter, the
On
option is
selected.
Select the signal level for the
simulation of the status input.
• High
• Low
High
Current input 1 to n simulation
–
Switch simulation of the
current input on and off.
• Off
• On
Off
Value current input 1 to n
In the
Current input 1 to n
simulation
parameter, the
On
option is selected.
Enter the current value for
simulation.
0 to 22.5 mA
0 mA
Current output 1 to n simulation
–
Switch the simulation of the
current output on and off.
• Off
• On
Off
Value current output 1 to n
In the
Current output 1 to n
simulation
parameter, the
On
option is selected.
Enter the current value for
simulation.
3.59 to 22.5 mA
3.59 mA
Frequency output simulation 1 to n
In the
Operating mode
parameter, the
Frequency
option is selected.
Switch the simulation of the
frequency output on and off.
• Off
• On
Off
Frequency value 1 to n
In the
Frequency output
simulation 1 to n
parameter,
the
On
option is selected.
Enter the frequency value for
the simulation.
0.0 to 12
500.0 Hz
0.0 Hz