Low flow cut off
The switch points for low flow cut off are user-selectable.
Galvanic isolation
The outputs are galvanically isolated from one another and from earth (PE).
Protocol-specific data
Manufacturer ID
0x11
Ident number
0x156D
Profile version
3.02
Device description files (GSD,
DTM, DD)
Information and files under:
•
•
www.profibus.org
Output values
(from measuring device to
automation system)
Analog input 1 to 8
• Mass flow
• Volume flow
• Corrected volume flow
• Carrier mass flow
• Target mass flow
• Density
• Reference density
• Temperature
• Carrier pipe temperature
• Electronic temperature
• Current input
The range of options increases if the measuring device has one or more
application packages.
Heartbeat Technology Application Package
Additional measured variables are available with the Heartbeat Technology
application package:
• Oscillation frequency 0
• Frequency fluctuation 0
• Oscillation amplitude 0
• Oscillation damping 0
• Oscillation damping fluctuation 0
• Exciter current 0
Heartbeat Technology Special Documentation
Digital input 1 to 2
• Empty pipe detection
• Low flow cut off
• Status verification
Totalizer 1 to 3
• Mass flow
• Volume flow
• Corrected volume flow
• Target mass flow
• Carrier mass flow