Proline t-mass I 300 HART
Incoming acceptance and product identification
Hauser
17
4.2.2
Sensor nameplate
Ser. no.:
Order code:
Date:
Ext.ord.cd.:
1
2
3
4
5
5
6
A0041926
2
Example of sensor nameplate
1
Name of the sensor
2
Order code
3
Serial number (ser. no.)
4
Extended order code (ext. ord. cd.)
5
Flow; length of sensor; pressure rating; nominal pressure; system pressure; medium temperature range;
permitted ambient temperature range (T
a
); explosion protection approval information, Pressure Equipment
Directive and degree of protection
6
Manufacturing date: year-month
Order code
The measuring device is reordered using the order code.
Extended order code
• The device type (product root) and basic specifications (mandatory features) are
always listed.
• Of the optional specifications (optional features), only the safety and approval-
related specifications are listed (e.g. LA). If other optional specifications are also
ordered, these are indicated collectively using the # placeholder symbol (e.g. #LA#).
• If the ordered optional specifications do not include any safety and approval-related
specifications, they are indicated by the + placeholder symbol (e.g. XXXXXX-ABCDE
+).
4.2.3
Symbols on measuring device
Symbol
Meaning
WARNING!
This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious
or fatal injury. To determine the nature of the potential hazard and the measures required to
avoid it, consult the documentation accompanying the measuring device.
Reference to documentation
Refers to the corresponding device documentation.
Protective ground connection
A terminal which must be connected to ground prior to establishing any other connections.