Parameter overview with brief description
Parameter
Prerequisite
Description
Selection / User entry /
User interface
Assign channel 1
The
Extended HistoROM
application
package is available.
Assign process variable to logging
channel.
• Off
• Temperature
• Mass flow
• Corrected volume flow
• FAD volume flow
• Volume flow
• Energy flow
• Heat flow
• Density
• Flow velocity
• Pressure
• 2nd temperature delta
heat
• Electronic temperature
• Current output 1
• Current output 2
• Current output 3
• Current output 4
Assign channel 2
The
Extended HistoROM
application
package is available.
The software options currently
enabled are displayed in the
Software option overview
parameter.
Assign process variable to logging
channel.
For the picklist, see the
Assign channel 1
Assign channel 3
The
Extended HistoROM
application
package is available.
The software options currently
enabled are displayed in the
Software option overview
parameter.
Assign process variable to logging
channel.
For the picklist, see the
Assign channel 1
Assign channel 4
The
Extended HistoROM
application
package is available.
The software options currently
enabled are displayed in the
Software option overview
parameter.
Assign process variable to logging
channel.
For the picklist, see the
Assign channel 1
Logging interval
The
Extended HistoROM
application
package is available.
Define the logging interval for data
logging. This value defines the time
interval between the individual data
points in the memory.
0.1 to 3
600.0 s
Clear logging data
The
Extended HistoROM
application
package is available.
Clear the entire logging data.
• Cancel
• Clear data
Data logging
–
Select the data logging method.
• Overwriting
• Not overwriting
Logging delay
In the
Data logging
parameter, the
Not
overwriting
option is selected.
Enter the time delay for measured
value logging.
0 to 999 h
Data logging control
In the
Data logging
parameter, the
Not
overwriting
option is selected.
Start and stop measured value logging.
• None
• start
• Stop
Data logging status
In the
Data logging
parameter, the
Not
overwriting
option is selected.
Displays the measured value logging
status.
• Done
• Delay active
• Active
• Stopped
Entire logging duration
In the
Data logging
parameter, the
Not
overwriting
option is selected.
Displays the total logging duration.
Positive floating-point