Proline t-mass I 300 HART
Operation
Hauser
127
Parameter
Prerequisite
Description
User interface
FAD volume flow
The
Air or compressed air
option is
selected in the
Measurement
application
parameter.
Displays the FAD volume flow that is
currently calculated.
Dependency
The unit is taken from the
FAD volume
flow unit
parameter (→ 86).
Signed floating-point
number
Energy flow
The
Energy
option is selected in the
Measurement application
parameter.
Shows the energy flow currently
calculated.
Signed floating-point
number
Temperature
–
Displays the temperature that is
currently measured.
Dependency
The unit is taken from the
Temperature unit
parameter
Signed floating-point
number
Density
–
Shows the density currently calculated.
Signed floating-point
number
Flow velocity
–
Shows the flow velocity currently
calculated.
Signed floating-point
number
Heat flow
The
Energy
option is selected in the
Measurement application
parameter
parameter.
Shows the heat flow currently
calculated.
Signed floating-point
number
10.4.2 System values
The
System values
submenu contains all the parameters needed to display the current
measured values for every system value.
Navigation
"Diagnostics" menu → Measured values → System values
‣
System values
Electronic temperature
Parameter overview with brief description
Parameter
Description
User interface
Electronic temperature
Indication of the current temperature of the electronics.
Signed floating-point number
10.4.3 "Totalizer" submenu
The
Totalizer
submenu contains all the parameters needed to display the current
measured values for every totalizer.
Navigation
"Diagnostics" menu → Measured values → Totalizer
‣
Totalizer
Totalizer value 1 to n
Totalizer overflow 1 to n