Proline Promass 83
Commissioning
Hauser
67
Recommended settings
!
Note!
Quick Setup automatically deactivates the function EMPTY PIPE DETECTION (6420) so that
the instrument can measure flow at low gas pressures.
"Gas Measurement" Quick Setup menu
HOME position
→
F
→
MEASURED VARIABLE (A)
MEASURED VARIABLE
→
O
→
QUICK SETUP (B)
QUICK SETUP
→
N
→
QS-GAS MEASUREMENT (1004)
Function No.
Function name
Setting to be selected (
P
)
(to next function with
F
)
1004
QS GAS MEASUREMENT YES
After
F
is pressed by way of confirmation, the Quick Setup menu
calls up all the subsequent functions in succession.
▾
6400
ASSIGN LOW FLOW
CUTOFF
On account of the low mass flow involved when gas flows are
measured, it is advisable not use a low flow cut off.
Setting: OFF
6402
ON-VALUE LOW FLOW
CUTOFF
If the ASSIGNMENT LOW FLOW CUTOFF function was not set to
"OFF", the following applies:
Setting: 0.0000 [unit]
User input: Flow rates for gas measurements are low, so the value
for the switch-on point (= low flow cut off) must be correspondingly
low.
6403
OFF-VALUE LOW FLOW
CUTOFF
If the ASSIGNMENT LOW FLOW CUTOFF function was not set to
"OFF", the following applies:
Setting: 50%
User input: Enter the switch-off point as a positive hysteresis in %,
referenced to the switch-on point.
▾
Back to the HOME position:
→
Press and hold down Esc key
X
for longer than three seconds or
→
Repeatedly press and release Esc key
X
→
Exit the function matrix step by step