Technical data
Proline Promass 83
110
Hauser
10.5
Power supply
Electrical connections
→
Page 25
ff
.
Supply voltage
85 to 260 V AC, 45 to 65 Hz
20 to 55 V AC, 45 to 65 Hz
16 to 62 V DC
Power consumption
AC: <15 VA (including sensor)
DC: <15 W (including sensor)
Switch-on current
:
• max. 13.5 A (< 50 ms) at 24 V DC
• max. 3 A (< 5 ms) at 260 V AC
Power supply failure
Lasting min. 1 power cycle:
• EEPROM and T-DAT save measuring system data if power supply fails.
• HistoROM/S-DAT: exchangeable data storage chip which stores the data of the sensor
(nominal diameter, serial number, calibration factor, zero point, etc.)
Potential equalization
No measures necessary.
Cable entries
Power supply and signal cables (inputs/outputs):
• Cable entry M20 × 1.5 (8 to 12 mm / 0.31 to 0.47 inch)
• Threads for cable entries, 1/2" NPT, G 1/2"
Connecting cable for remote version:
• Cable entry M20 × 1.5 (8 to 12 mm / 0.31 to 0.47 inch)
• Threads for cable entries, 1/2" NPT, G 1/2"
Cable specifications remote
version
Remote version