background image

ST100 Series

Thermal Mass Flow Meter

HART Operation

Manual 

Fluid Components International LLC (FCI).  All rights reserved. 

Содержание ST100 series

Страница 1: ...ST100 Series Thermal Mass Flow Meter HART Operation Manual Fluid Components International LLC FCI All rights reserved...

Страница 2: ...I Disclosure of this data to you is expressly conditioned upon your assent that its use is limited to use within your company only and does not include manufacture or processing uses Any other use is...

Страница 3: ...Data Organization 5 Device Description Files 6 Service Data Operation 7 Setting the ST100 for the HART Protocol Operation 9 ST100 HART Command List 10 ST100 HART Universal Commands 10 ST100 HART Commo...

Страница 4: ...ii Fluid Components International LLC 06EN003404 Rev A ST100 Series HART INTENTIONALLY LEFT BLANK...

Страница 5: ...ses data types and status reporting sup ported by the Protocol Common Practice HART Commands A collection of commands applicable to a wide range of devices These commands shall be supported by devices...

Страница 6: ...to wiring connections is obtained through one of the four conduit outlets see Figure 6 below Figure 1 HART Output Wiring Table The HART connections for the ST100 are located in the back panel The conn...

Страница 7: ...ST100 Series HART Fluid Components International LLC 3 Figure 3 Detail External Power Supply connection for Non Network Figure 2 Detail Internal Power Supply connection for Non Network...

Страница 8: ...Network In Network configuration the analog current signal serves just to energize the two wire devices providing a current of 4 mA per instrument In multidrop mode up to 15 field devices are connect...

Страница 9: ...are available in all configurations of the ST100 flow meter For example not all configurations have Process Pressure and instruments that output Mass Flow or Volumetric flow the Flow Totalizer may be...

Страница 10: ...he standard EDDL files located in the folder A67F0101 and the Emerson 375 and 475 files located in the folder DDP A67F0101Folder 0101 fm8 A67F0101 ddl DDP Folder 00A67F0101 hdd 00A67F0101 hhd 0101 fm8...

Страница 11: ...I s EDDL files loaded The same information seen by the 475 is shown in the DCS when the ST100 HART EDDL files are loaded ST100 Basic Setup The Basic Setup function includes the ability to review and c...

Страница 12: ...ade to the configuration of calibration parameters will be lost when the Factory Reset command is executed ST100 Configuration The configuration functions facilitate the setup of the individual 4 20 m...

Страница 13: ...tocol with instrument power ON In normal operating conditions connect the PC with the configurator software to the ST100 USB port using FCI s cable P N 022646 To configure the ST100 for HART open the...

Страница 14: ...CE TYPE EXPAND DEV TYPE ENUM 2 BYTE MINIMUM PREAMBLES REQUEST MIN PREAMBLES UNSIGNED 8 HART PROTOCOL MAJOR REV HART PROTOCOL REV UNSIGNED 8 DEVICE REVISION LEVEL DEV REV LEVEL UNSIGNED 8 DEVICE SOFTWA...

Страница 15: ...LLING ADDRS POLLING ADDRESS CHAR 1 BYTES LOOP CUR MODE CHAR 1 BYTES 7 READ LOOP CONFIGURATION POLLING ADDRS CHAR 1 BYTES LOOP CUR MODE CHAR 1 BYTES 8 READ DYNAMIC VARIABLE ENUM CLASSIFICATIONS 4 BYTES...

Страница 16: ...LIMIT PV UPPER SENSOR LIMIT FLOAT 4 BYTES LOWER SENSOR LIMIT PV LOWER SENS LIMITS FLOAT 4 BYTES MIN SPAN PV MIN SPAN FLOAT 4 BYTES 15 READ OUTPUT INFORMATION ALARM SELECT CODE ALRM SEL CODE ENUM 1BYT...

Страница 17: ...BITSTRING 6 BYTES DESCRIPTOR DESCRIPTOR BITSTRING 12 BYTES DATE DATE CHAR 3 BYTES 19 WRITE FINAL ASSEMBLY NUMBER ASSEMBLY NUMBER ASSEMB UNSIGNED 24 20 READ LONG TAG LONG TAG LONG TAG BITSTRING 32 BYTE...

Страница 18: ...CONFIG CHANGE FLAG UNSIGNED 8 40 ENTER EXIT FIXED CURRENT MODE IN mA I MODE SELECT Value 0 means exit fixed current mode FLOAT 4 BYTES 42 PERFORM DEVICE RESET RESET INSTRUM UNSIGNED 8 44 WRITE PV UNI...

Страница 19: ...TE SECONDARY DEVICE VARIABLE N A TERTIARY DEVICE VARIABLE N A QUATERNARY DEVICE VARIABLE N A ST100 HART Device Specific Commands The ST100 HART supports 20 Device Specific commands HART COMM NUMB HART...

Страница 20: ...NITS CODE FLOW CODE UNSIGNED 8 TEMPERATURE UNITS CODE TEMP CODE UNSIGNED 8 TOTALIZER UNITS CODE TOTAL CODE UNSIGNED 8 PRESSURE UNITS CODE optional PRESS CODE UNSIGNED 8 148 READ PLENUM INFORMATION PIP...

Страница 21: ...TPUT CHANNEL 2 PARAMETERS D A SETTING FOR 4mA OUT OUTZ2 UNSIGNED 16 D A SETTING FOR 20mA OUT OUTF2 UNSIGNED 16 CHANNEL 2 OUT VARIABLE CHA_2_PRO_VAR UNSIGNED 8 164 READ 4 20mA OUTPUT CHANNEL 2 PARAMETE...

Страница 22: ...LOW VALUE SENSOR 3 FLOW3_VAL FLOAT 4BYTES TEMPERATURE VAL SENSOR 3 TEMP3_VAL FLOAT 4BYTES PRESSURE VALUE SENSOR 3 PRESS3_VAL FLOAT 4BYTES FLOW VALUE SENSOR 4 FLOW4_VAL FLOAT 4BYTES TEMPERATURE VAL SEN...

Страница 23: ...the primary variable its range will be returned 45 4 bytes Trim the zero or lower end point value of the loop current exactly to its minimum 46 4 bytes Trim the gain or upper end point value of the lo...

Страница 24: ...at its core is a device driver There are two DTM categories 1 Device DTMs which connect to the field device configuration components 2 Communication DTMs which connect to the software communication c...

Страница 25: ...or HART protocol communication Install device DTM prior to PACTWare and Comm_DTM components Once device DTM is downloaded successfully run it on the PC After that download and install Comm_DTM onto th...

Страница 26: ...HART 22 Fluid Components International LLC Now invoke PACTware program Select device from the menu and click on Add Device tab Right click on the device and select Parameter change correct COM port fo...

Страница 27: ...ST100 Series HART Fluid Components International LLC 23 Right click on the device and add Device DTM from the list...

Страница 28: ...ck on the device and click on the Connect Select Online parameterization pull down menu command to check the communication between ST100 HART DTM and ST100 Field Device Once you are done with the prev...

Страница 29: ...information of the instrument such as manufacturer model device ID serial number tag poll address and so on Process Data ST100 HART DTM file shows all process data variables on a single screen with t...

Страница 30: ...l as for the ST100 meter front end FE This tab lets the cus tomer or technician diagnose troubleshoot meter issues Basic Setup Basic Setup has various ST100 settings including Units Plenum and Totaliz...

Страница 31: ...this tab to specify the height width and or diameter for the pipe duct Specify dimension units as inches or millimeters Advance Setup Use this tab to change DAC values per user requirements and selec...

Страница 32: ...100 product of family supports PDM Process Device Manager functionality through the HART Protocol 7 3 Fluid Components International provides PDM files for the ST100 HART device Shown below are exampl...

Страница 33: ...ST100 Series HART Fluid Components International LLC 29 Process Data Screen Diagnostic Screen Basic Setup Screen...

Страница 34: ...ST100 Series HART 30 Fluid Components International LLC Advance Setup Screens Basic Screen Pipe Duct Information...

Страница 35: ...ST100 Series HART Fluid Components International LLC 31 Live Data from ST100 HART Device Through PDM...

Страница 36: ...d 48 returns 25 bytes of data with the following status information for status bytes 0 through 5 The remaining status bytes are reserved for future use Listed below are definitions for status bytes 0...

Страница 37: ...ardware 4 2 Flow Sensor A D Counts Under Min Limit Hardware 4 3 Flow Sensor Signal Exceeds 120 Limit Hardware 4 4 Flow Sensor Signal Exceeds 100 Signal Hardware 4 5 Flow Sensor Signal Exceeds A D Limi...

Страница 38: ...elf Check Mode No Process Data Available 4 Reserved 5 Reserved 6 Reserved 7 Reserved Status Byte 5 Not used bits are always set to 0 The bits may be set as errors are detected But these errors are not...

Страница 39: ...Interface Data transmission rate 1200Hz Signal coding Bell 202 Current Physical layer Supported communication Publisher Subscriber HART Commands Universal Commands Common Practice Commands Manufacture...

Страница 40: ...ST100 Series HART 36 Fluid Components International LLC INTENTIONALLY LEFT BLANK...

Страница 41: ...ST100 Series HART Fluid Components International LLC 37 Appendix A Drawings Channel 1 HART Connection Before April 2012...

Страница 42: ...ST100 Series HART 38 Fluid Components International LLC INTENTIONALLY LEFT BLANK...

Страница 43: ...by facsimile if all possibilities have been exhausted with the authorized factory representative Our Fax number is 1 760 736 6250 it is available 7 days a week 24 hours a day By E Mail FCI Customer Se...

Страница 44: ...ithout the prior written consent of FCI Visit FCI on the Worldwide Web www fluidcomponents com FCI World Headquarters 1755 La Costa Meadows Drive San Marcos California 92078 USA Phone 760 744 6950 Tol...