Proline Promass 83
Technical data
Hauser
121
Example for max. measured error
a0004611
Fig. 54:
Max. measured error in % o.r. (example: Promass I, DN 25)
Flow values (example)
Repeatability
• Mass flow and volume flow (liquids): ±0.05% o.r.
• Mass flow (gases): ±0.25% o.r.
• Density (liquids): ±0.00025 g/cm
3
• Temperature: ±0.25 °C ± 0.0025 · T °C; ±0.5 °F ± 0.0015 · (T - 32) °F
Influence of medium temperature
When there is a difference between the temperature for zero point adjustment and the
process temperature, the typical measured error of the sensor is ±0.0002% of the full scale
value / °C (±0.0001% of the full scale value/°F).
0
±0.5
±0.2
±1.0
[%]
0
1
2
4
6
8
10
12
14
16
18
t/h
Turn down
Flow
Maximum measured error
[kg/h]
[lb/min]
[% o.r.]
250 : 1
72
2.646
1.875
100 : 1
180
6.615
0.750
25 : 1
720
26.46
0.188
10 : 1
1800
66.15
0.100
2 : 1
9000
330.75
0.100
Design fundamentals