Technical data
Proline Promass 83
108
Hauser
Measuring ranges for gases (Promass A)
Measuring ranges for gases (Promass I)
Measuring ranges for gases (Promass X)
Calculation example for gas:
• Sensor type: Promass F, DN 50
• Gas: air with a density of 60.3 kg/m³ (at 20 °C and 50 bar)
• Measuring range (liquid): 70000 kg/h
• x = 90 (for Promass F DN 50)
Max. possible full scale value:
g
max(G)
=
g
max(F)
· r
(G)
÷ x [kg/m³] = 70000 kg/h · 60.3 kg/m³ ÷ 90 kg/m³ = 46900 kg/h
Recommended full scale values
See
→
Page 127
ff
. ("Limiting
fl
ow")
Operable flow range
Greater than 1000 : 1. Flows above the preset full scale value do not overload the amplifier,
i.e. totalizer values are registered correctly.
DN
x
[mm]
[inch]
1
1/24
32
2
1/12
32
4
1/8
32
DN
x
[mm]
[inch]
8
3/8
60
15
½
80
15 FB
½ FB
90
25
1
90
25 FB
1 FB
90
40
1 ½
90
40 FB
1 ½ FB
90
50
2
90
50 FB
2 FB
110
80
3
110
FB = Full bore versions of Promass I
DN
x
[mm]
[inch]
350
14
200