Wiring
Proline Promass 83
26
Hauser
4.1.2
Cable specification, connecting cable
The specifications of the cable connecting the transmitter and the sensor of the remote
version are as follows:
• 6 × 0.38 mm2 PVC cable with common shield and individually shielded cores
• Conductor resistance:
≤
50 W/km
• Capacitance core/shield:
≤
420 pF/m
• Cable length: max. 20 m (65 ft)
• Permanent operating temperature: max. +105 °C (+221 °F)
!
Note!
The cable must be installed securely, to prevents movement.
4.2
Connecting the measuring unit
4.2.1
Transmitter connection
#
Warning!
• Risk of electric shock. Switch off the power supply before opening the device. Do not install
or wire the device while it is connected to the power supply. Failure to comply with this
precaution can result in irreparable damage to the electronics.
• Risk of electric shock. Connect the protective ground to the ground terminal on the
housing before the power supply is applied (not required for galvanically isolated power
supply).
• Compare the specifications on the nameplate with the local supply voltage and frequency.
The national regulations governing the installation of electrical equipment also apply.
1.
Unscrew the connection compartment cover (f) from the transmitter housing.
2.
Feed the power supply cable (a) and the signal cable (b) through the appropriate cable
entries.
3.
Perform wiring:
– Wiring diagram (aluminum housing)
– Wiring diagram (stainless steel housing)
– Wiring diagram (wall-mount housing)
– Terminal assignment
4.
Screw the cover of the connection compartment (f) back onto the transmitter housing.
a0004582
Fig. 22:
Connecting the transmitter (aluminum field housing). Cable cross-section: max. 2.5 mm2
a
Cable for power supply: 85 to 260 V AC, 20 to 55 V AC, 16 to 62 V DC
Terminal
No. 1
: L1 for AC, L+ for DC
Terminal
No. 2
: N for AC, L- for DC
b
Signal cable: Terminals
Nos. 20–27
c
Ground terminal for protective ground
d
Ground terminal for signal cable shield
e
Service adapter for connecting service interface FXA193 (FieldCheck, FieldCare)
f
Cover of the connection compartment
g
Securing clamp
b
b
c
d
a
a
2
1
– 27
– 25
– 23
– 21
+ 26
+ 24
+ 22
+ 20
L1 (L+)
N (L-)
g
f
e
Содержание HART Proline Promass 83