Automatic settings
Control System KNX WS1000 Color
• Status: 18.04.2016 • Errors excepted. Subject to technical changes.
During
frost, wind or rain alarm
all windows are closed and cannot be manually
opened. Gap ventilation during a rain alarm is an exception; it only restricts the win-
dow's range of motion in automatic mode.
As soon as a connected
air conditioner is activated
, all windows are closed. They
are then in automatic mode but can be immediately operated again. The delay time for
the ventilation block engaged by an air conditioner can be adjusted.
System > Automatic Settings > General Settings > Ventilation Block
3.3. Adjust ventilation block
Ventilation settings
The settings are only executed if a window is in automatic mode and none of the alarm
functions named above is active.
Highest priority is assigned to
time closure
, followed by the
outdoor temperature-
block
(keep closed),
timed ventilation
(open), the incoming
air temperature-block
(keep closed) and
night-time re-cooling
(open).
This means that e.g. timed ventilation or night-time re-cooling will only occur, when
the outdoor temperature lies over the pre-set value for the outdoor temperature block.
The
automatic ventilation according to temperature
or relative humidity is only
performed if no block is active.
Setting of the automatic
The automatic window functions can be accessed by pressing the buttons:
Now you can select individual windows and adjust their settings. For each window the
following settings can be changed:
Press the button to select the indoor sensor the control system will use for this window
(Pre-setting: first sensor in the list). As long as “
No Sensor
” is selected, the indoor
temperature and air humidity will not be taken into account.
Confirm your setting with the
OK
button.
Press the button to set the indoor temperature above which the window will be
opened. Until an indoor sensor is selected, the indoor temperature will be disregarded.
Automatic
settings
Window
System
Sensor Selection
Indoor Temp.