36
Automatic settings
Control System KNX WS1000 Color
• Status: 18.04.2016 • Errors excepted. Subject to technical changes.
Enable: If the blind respectively the roller shutter should be closed at night, select
Yes
.
Disable: If the blind respectively the roller shutter should remain open at night, select
No
(default setting).
Confirm your setting with the
OK
button.
The threshold value, above which twilight/night will be recognised, can be adjusted.
System > Automatic Settings > General Settings > Twilight
3.3. Adjust twilight value
Note to night closing function and outdoor temperature block:
If the outdoor temperature is below the blocking temperature (see “Outdoor Temper-
ature” settings), the blinds and roller shutters will close, but will not open automatical-
ly. If the blind/shutter fails to move up in the morning, please check if the hangings are
not frozen or the rails iced. When the shading is free, you can move the hangings up
by hand.
The drive and hangings may be damaged if a firmly frozen
outdoor shading is moved!
Press the button to set the closure time. Press Select to select the time during which
the blind respectively the roller shutter will be closed. Activate one or more periods on
the list. The periods can be individually customised (see below).
Confirm your setting with the
OK
button.
To change any of the time periods, press
Timer
.
Set timer, page 59
Note to timer closing function and outdoor temperature block:
If the outdoor temperature is below the blocking temperature (see "Outdoor Tempera-
ture" settings), the blinds and roller shutters will close, but not open automatically. If
the blind/shutter fails to move up after the preset period, please check if the hangings
are not frozen or the rails iced. When the shading is free, you can move the hangings
up by hand.
The drive and hangings may be damaged if a firmly frozen
outdoor shading is moved!
Press the button to set the outdoor temperature block. The block only applies to auto-
matic operation; no shading occurs based on light intensity or the position of the sun.
Timed closure